9
Technical data
38
Manual
– ECDriveS® ECIO
9
Technical data
9.1
Basic Device
The following tables list the technical data for the device:
9.1.1
General
General
Power supply Voltage
24 V +/- 10 %
Standby current consumption
less than 70mA
Minimum Operating Voltage
21 V
Maximum Operating Voltage
30 V
Storage temperature
-40 °C to 120 °C
Ambient Operating temperature
0 °C to 50 °C
Humidity
5 % to 95 % non-condensing
Vibration
0.152 mm displacement, 1G peak
Mechanical Shock
20G peak for 10ms duration (1.0 ms)
Enclosure IP Rating
IP54
Maximum current (for 8 outputs)
2.4 A
9.1.2
Inputs
Inputs
PNP/NPN Auto-sensing (Default)
Up to 8 per module - 2 inputs per port
Programmable Push-Pull selectable
Minimum ON current
1.5 mA
Maximum OFF current
0.4 mA
Short Circuit protection( per side)
500mA max
Sensor port inputs are auto-sensing for the connected circuit type of either PNP or NP N.
Please note that both sourcing and sinking current will activate the input.
Each port utilizes load detection circuits between the +24V (Pin 1) and Gnd (Pin 3). Th is
circuit provides input to the processor to detect if a power consuming device is c onnect-
ed. Short circuit between Pin 1 and Pin 3 can cause damage to the load detection circuit
and render this function inoperable.
9.1.3
Outputs
Outputs
PNP only
Output count
Up to 8 per module
Maximum current ( per Output)
300 mA
Short-circuit protection threshold( per
Output
500 mA