Manual – MOVI-PLC® advanced DHF41B DeviceNet and PROFIBUS DP-V1 Fieldbus Interfaces
93
11
Configuring a C1 master
Functions of PROFIBUS DP-V1
• Comment regarding the function module:
11.4.3 Technical data of DP-V1 for MOVI-PLC
®
advanced
DHF41B
12102AEN
Write service: x2h, fixed setpoint: P160, index 8489d = 2129h
Wiring of FB:
"Drive_IO_Address": (INT) Input address of the process data =>Hardware config.
"bService": (BYTE) Read: 01h; Write 02h, volatile writing 03h
"bAxis": (BYTE) Sub address/SBUS address of lower-level MC07
"wParameterindex": (WORD) Parameter index => "MC07 Communication" manual
"wSubIndex": (WORD) MOVILINK subindex = 0
"dwWriteData": (DWORD) Parameter data for WRITE service
"InstanzDB_SFB52(BLOCK_DB) Instance DB for the SFB52
"InstanzDB_SFB53(BLOCK_DB) Instance DB for the SFB53
"fActivate" (BOOL) Activation bit
"fBusy": (BOOL) Parameter service is active
"fDone": (BOOL) Parameter service was executed
"bError" (BYTE) No error = 0; S7 error = 1; TimeOut = 2;
MOVILINK error = 3
"dwData": (DWORD)bError = 0 => Parameter value after READ service
bError = 1 => S7 error code
GSD file for DP-V1:
SEW_6007.GSD
Module name for project planning:
MOVI-PLC
Number of parallel C2 connections:
2
Supported data set:
Index 47
Supported slot number:
Recommended: 0
Manufacturer code:
10A hex (SEW-EURODRIVE)
Profile ID:
3A
C2 response timeout
1 s
Max. length C1 channel:
240 bytes
Max. length C2 channel:
240 bytes
0
0
I