Manual – MOVI-PLC® advanced DHF41B DeviceNet and PROFIBUS DP-V1 Fieldbus Interfaces
63
10
Settings in MOVI-PLC® advanced DFHF41B
PROFIBUS DP-V1 Operating Characteristics
10.3.1 Status of the PROFINET fieldbus interface
The
FbusGetInfo
function block makes the status and some display parameters of the
fieldbus interface available for the IEC program and diagnostics.
If there is no communication with the fieldbus master, the output
Error
is set to
TRUE
.
During an active fieldbus connection, the output
Done
is set to
TRUE
, and the outputs
Address
,
Baud rate
,
Timeout
and
Bus type
show the respective parameters as they
were set via the DIP switches of the DHF41B option or via the PLC.
Checking the
process data
communication
The MOVI-PLC
®
advanced
DHF41B can now read the actual values and write setpoints.
The process data should correspond to the values displayed in the PLC Editor or in the
diagnostics plug-in of the active IEC program in MOVITOOLS
®
MotionStudio.
If there is no IEC program in MOVI-PLC
®
, you can create one as follows:
• Open the context menu of the PLC in MOVITOOLS
®
MotionStudio and run the
project wizard "Create new PLC Editor project" (see following figure).
• Use the wizard to create a new AxisControl project and upload it to MOVI-PLC
®
advanced
DHF41B using the menu item "Online login".
12046AXX
12049AXX
0
0
I