6
The Common Industrial Protocol (CIP)
DeviceNet Operating Characteristics
Fieldbus
parameters
MOVI-PLC
®
advanced DHF41B
Supported
services
Instance
Access
Group
Name
Meaning
1
Get/Set
Device
parameter
PD configuration
Process data configuration
2
Get
Timeout time
Timeout interval
3
Get
Fieldbus type
DeviceNet
4
Get
Baud rate
Baud rate via DIP switches
5
Get
Station address
MAC-ID via DIP switches
6 - 69
Get
PO
monitor
PO1 setpoint ...
PO64 setpoint
Monitor of the
process output data words
70 - 133
Get
PI monitor
PI1 actual value ...
PI64 actual value
Monitor of the
process input data words
TIP
The data format for these instances deviates from the SEW fieldbus profile to meet the
DeviceNet specification.
Service code [hex]
Service Name
Class
Instance
0E
Get_Attribute_Single
X
X
10
Set_Attribute_Single
-
X
0
0