![SEW-Eurodrive DHF41B Скачать руководство пользователя страница 75](http://html.mh-extra.com/html/sew-eurodrive/dhf41b/dhf41b_manual_1250085075.webp)
Manual – MOVI-PLC® advanced DHF41B DeviceNet and PROFIBUS DP-V1 Fieldbus Interfaces
75
11
Introduction to PROFIBUS DP-V1
Functions of PROFIBUS DP-V1
11.1.4 DP-V1 services
The DP-V1 expansions offer new services, which can be used for acyclical data
exchange between master and slave. The system distinguishes between the following
services:
11.1.5 DP-V1 alarm handling
In addition to the acyclical services, the DP-V1 specification also defines extended
alarm handling. Alarm handling now distinguishes between different alarm types. As a
result, unit-specific diagnostics cannot be evaluated in DP-V1 operation using the
"DDLM_SlaveDiag" DP-V0 service. DP-V1 alarm handling has not been defined for
drive engineering as an inverter does not usually transfer its status information via
cyclical process data communication.
C1 master
Connection type: MSAC1 (master/slave acyclical C1)
READ
Read data record
WRITE
Write data record
C2 master
Connection type: MSAC2 (master/slave acyclical C2)
INITIATE
Establish C2 connection
ABORT
Disconnect C2 connection
READ
Read data record
WRITE
Write data record
0
0
I
Содержание DHF41B
Страница 2: ...SEW EURODRIVE Driving the world ...