7
Project planning and startup with MOVITOOLS
®
MotionStudio
Communication via Ethernet
Manual – DHE/DHF/DHR21B (standard) and DHE/DHF/DHR41B (advanced)
51
7.3.2
Configuring the communication channel via USB
Proceed as follows:
1. Establish the communication channel via USB, see chapter
"
communication and scanning the network" (→
45).
2. Set the communication parameters.
Communication
parameter
Description
Information
Timeout
Waiting time in [ms] that the master waits
for a response from the slave after it has
made a request.
Default setting:
350 ms
7.4
Communication via Ethernet
7.4.1
Connecting the device with the PC via Ethernet
The following figure shows the network with direct communication using Ethernet:
[1]
EURODRIVE
EURODRIVE
[4]
[3]
[2]
ETHERNET
1193501835
[1]
Engineering PC with Ethernet interface
[2]
Ethernet connection
[3]
Switch
[4]
Devices (examples) with Ethernet interfaces
Parameter requests from the
MOVITOOLS
®
MotionStudio engineering software are
transferred to a switch [3] via Ethernet [2] from an engineering PC [1] using the Ether-
net interface. The switch [3] then directly passes on the parameter requests to the Eth-
ernet interface of the devices [4].
22900055/EN – 08/2016