6
Electrical installation
Terminal assignment and DIP switches
Manual – DHE/DHF/DHR21B (standard) and DHE/DHF/DHR41B (advanced)
28
Assignment
No.
Name
Function
X26
1
CAN 1H
System bus CAN 1 high
2
CAN 1L
System bus CAN 1 low
3
DGND
Reference potential for controller/CAN 1
4
Reserved
–
5
Reserved
–
6
DGND
Reference potential for controller/CAN 1
7
DC 24 V
Voltage supply controller
6.2.3
X30-1/X30-2: Ethernet 3/Ethernet 4 connection
Function
Connection to Ethernet network
INFORMATION
•
According to IEC 802.3, the maximum cable length for 10/100 MBaud Ethernet
(10 BaseT/100 BaseT), e.g. between 2 network stations, is 100 m.
•
SEW‑EURODRIVE recommends that you do not directly connect third-party end
devices to the DHR21B/41B option in order to minimize the load on the end
devices in EtherNet/IP networks caused by undesired multicast data traffic. Con-
nect devices from third-party manufacturers via a network component that sup-
ports the IGMP snooping functionality (e.g. managed switch). Managed switches
with IGMP snooping functionality are not required for PROFINET IO and Modbus/
TCP networks.
Connection type
To connect DHR21B/41B to the Ethernet network, connect Ethernet interface X30-1
or X30-2 (RJ45 plug connector) to the other network stations using a category 5,
class D twisted-pair cable in accordance with IEC 11801 edition 2.0. The integrated
switch assists you in implementing a line topology and provides auto-crossing func-
tions.
Assignment
No.
Name
Function
X30-1
Ethernet 3
Ethernet default assignment
X30-2
Ethernet 4
22900055/EN – 08/2016