49
49
LED Status Indicators
49
Appendix A
LED Status Indicators
The LED pins can be used to monitor the module status. They can be used to drive
external LEDs. It is assumed that the LED lights when the electrical level of the
corresponding pin is high.
The general-purpose LEDs (GPLED and GPLED2 pins) are configured with the
setLEDMode
command. The default configuration is:
•
GPLED: configured as PVTLED by default;
•
GPLED2: configured as RTKLED by default.
The following LED modes are supported.
GPLED mode LED Behaviour
PVTLED
LED lights when a PVT solution is available.
RTKLED
LED is off if the PVT is not in RTK mode, blinks in float RTK and is solid
on in fixed RTK.
DIFFCORLED
Differential correction indicator. In rover PVT mode, this LED reports
the number of satellites for which differential corrections have been
provided in the last received differential correction message (RTCM
or CMR).
LED behaviour
Number of satellites with corrections
LED is off
No differential correction message received
blinks fast and
continuously (10 times per
second)
0
blinks once, then pauses
1, 2
blinks twice, then pauses
3, 4
blinks 3 times, then pauses 5, 6
blinks 4 times, then pauses 7, 8
blinks 5 times, then pauses 9 or more
The LED is solid ’ON’ when the
module is outputting differential
corrections as a static base station.
TRACKLED
LED behaviour
Number of satellites in tracking
blinks fast and
continuously (10 times per
second)
0
blinks once, then pauses
1, 2
blinks twice, then pauses
3, 4
blinks 3 times, then pauses 5, 6
blinks 4 times, then pauses 7, 8
blinks 5 times, then pauses 9 or more