S E N T I N E L
P R O P R I E T A R Y I N F O R M A T I O N A N D M A T E R I A L S O F U N I T E C I N C .
76
Table 3. IDX Program Configuration
Coins
IDX Rotary Switch
Position
Signal Line
Number of Output
Pulses
Token 1
1
3
Determined by User
Token 2
2
3
Determined by User
Token 3
3
3
Determined by User
Token 4
4
3
Determined by User
$1-Coin
5
2
1
Quarters
6
1
1
11.6.2
Programming the IDX to Accept $1 Coins
The number of pulses is programmed by pressing the push-button the desired number of times prior to
insertion of the sample/programming coins.
1.
Set the rotary-switch to the position labeled number 5.
2.
Press the button located immediately to the left of the switch once.
3.
Drop six different dollar coins through the acceptor and verify that the light (LED) blinks
after the last coin has been entered.
4.
Move the rotary switch back to the position labeled ‘0’.
11.6.3
Programming the IDX to Accept Quarters
Follow the steps below to program the IDX to accept quarters.
1.
Remove the front cover by pushing it in and up from the bottom right corner of the main
body. (This is located near the phone number.)
2.
Locate the rotary-switch and set it to the position labeled number 6.
3.
Press the button located immediately to the left of the switch once.
4.
Drop six different quarters through the acceptor and verify that the light (LED) blinks after
the last quarter has been entered.
5.
Move the rotary switch back to the position labeled ‘0’.
11.6.4
Site-Specific Tokens
Before you begin programming, be sure that you have six of each token you plan to program. You are
responsible for supplying your own bi-metal tokens. Tokens are not available through Unitec.