SIE-CNTEP-1100002104-2014
LCFS
AV6418 OTDR
145
Average loss value
of optical fiber
measured is not
accurate
a. Large error in
length of the
tested optical
fiber.
b. Front end of the
test trace
tails too long
a. Refer to the above
item to measure the
length
of optical fiber
accurately.
b. Clean splice of the
tested optical fiber or
add in
a little matching fluid
and retest the trace
afterwards.
There isn
’
t test
waveform displayed
on screen, except for
the front end
reflection peak; or
the front end
reflection peak has
long tailing
Fiber end is
polluted;
Wipe the fiber end
with absolute ethyl
alcohol.
Fiber end inside
the optical
output port
connector of
instrument is
polluted
Take down the optical
output port connector
and
wipe it with the
absolute ethyl alcohol.
Ceramic core
inside optical
output port
connector
(flange) is
damaged, which
causes crack or
Replace the flange.
Página No.157 LCFS
CONVALIDACIÓN DE ERRORES DEL PROCESO:
“ADQUISICIÓN DE OTDR (OPTICAL TIME DOMAIN REFLECTOMETER) – REDES GPON/
FTTH/ SDH"