Page 90
FlexPS Product Guide
Proc
ess
or
Controls
•
calibration adjustments via the Universal Configuration Module
(Windows-based software application)
Inputs
•
2 sensor cable inputs (1 per zone)
•
2 voltage sensing auxiliary device/self-test/audio activation inputs
Outputs
•
4 form C relay outputs 30 VDC @ 1 A maximum, non-inductive load
user-configurable relay response
•
600
impedance audio output
LED indicators
•
power
•
one per relay
•
UCM connected
•
Enclosure door open
•
diagnostic activity
Supervision
•
mechanical enclosure tamper switch
•
sensor wires
•
lead-in cable
•
processor operation
Temperature
•
-40º to +70ºC (-40º to +158º F)
Relative humidity
•
0 to 95%, non-condensing
Frequency response
•
selectable frequency response band
•
100 - 900 Hz