Installing the sensor cable
Page 32
FlexPS Product Guide
DO NOT remove the protective gel inside the enclosure.
7.
Snap the enclosure shut ensuring that both tabs are securely locked in the slots.
8.
Attach the enclosure to the fence.
Installing terminators on Mark 2 cable
1.
At the cut end of the sensor cable, carefully, remove 2.5 cm (1 in.) of the outer jacket.
DO NOT nick the braided shield.
2.
Separate and peel back the exposed braided shield.
3.
Tightly twist the separated strands of shield into a single conductor, and then carefully remove
6 mm (0.25 in.) of the insulator from the center conductor.
DO NOT nick the center conductor.
Figure 27: Preparing the termination enclosure
Note
Form a 15 cm drip loop and install the enclosure horizontally to
protect the cable entry points from rain and run off.
Figure 28: Mounting the termination enclosure
Figure 29: Preparing Mark 2 sensor cable step 1 & 2
5
6
7
8
15 cm (6 in.)
1
2