Setup
FlexPS Product Guide
Page 75
Input configuration procedure (Remote control mode)
1.
Select the Aux Cfig tab on the UCM window.
2.
From the Supervision drop down, select the desired supervision scheme for the input.
3.
Select the Resistor 1 value, if applicable.
4.
Select the Resistor 2 value, if applicable.
5.
Set the Noise Tolerance, if required.
6.
Set the Line Drop, if required.
7.
Set the Filter Window.
8.
Repeat this procedure if there is a second connected input.
9.
Save the UCM configuration file.
10. Select the Download button to save the configuration changes to the processor.
Input option
UCM selection
Alarm
relay
Supervision relay R1
R2
unsupervised
NO
---
---
---
single resistor
supervision
NO
NC
5.1 k
---
dual resistor
supervision
NO
NO/NC
4.3 k
820
unsupervised
NC
---
---
---
single resistor
supervision
NC
NO
5.1 k
---
dual resistor
supervision
NC
NO/NC
5.1 k
820
Table 5: Selectable input configurations
R1 values (single resistor
supervision)
R1 values (double resistor
supervision)
R2 values (double resistor
supervision)
820
1.1 k
820
1 k
2.2 k
1.1 k
1.1 k
4.3 k
2.2 k
1.2 k
5.1 k
5.6 k
1.5 k
5.6 k
2.2 k
3.3 k
4.7 k
5.1 k
5.6 k
Table 6: Selectable resistor values