SENS EnerGenius Technical Manual 

Service hotline: 1.800.742.2326 
                           1.303.678.7500  

This manual contains important safety, installation and operating instructions for SENS battery charger model 
NRG12-10 (configured for 12V,10A only), NRG24-10 (configured for 24V, 10A only) and NRG22-10 (field 
configurable for 12V or 24V, 10A).

 

INSTALLATION INSTRUCTIONS 

WARNING: 
ONLY TRAINED AND QUALIFIED                    
PERSONNEL MAY INSTALL AND SERVICE THIS UNIT. 

MODEL NUMBER CONFIGURATION

 

Model Number Breakout 

                                            

                             

NRG 22-10-

 

 
 

                   Model         Output               Output             Input Voltage           Alarm System       Agency     Category  
                                      Voltage              Current            Frequency               Code                             
              

                         

                                     12: 12 volts        10: 10 Amps    H: 120/208-240V,      C:  5 Alarms        L: UL        S: Standard 
                                      24: 24 volts                                     50/60 Hz                1: 1 Alarm          C-UL 
                                      22: 12/24 volts                                R: 120/208-240V, 
                                                                                             60 Hz 

  

 

            

                                             

                                                                NOTE: Not all configurations are available on all models.

    

                                      

Contact the factory for confirmation.

   

                                      

**UL listed, CSA certified 

                                                                             *UL listed, CSA certified and CE marked

                                                              

6” (150 mm) minimum 
ventilation clearance 
top and bottom 

2” (50 mm) minimum 
ventilation clearance 
on each side 

Mount to vertical surface of 3/4” (19 mm) plywood 
or other material of equal strength and durability,  
using four mounting screws 1/4” (6 mm) diameter. 

Содержание EnerGenius NRG22-10

Страница 1: ...y Charger SENS Part Number Document Revision DCN Number Date 101295 L 105749 July 28 2009 Installation or service questions Call SENS at 1 800 742 2326 303 678 7500 between 8 a m and 5 p m Mountain Ti...

Страница 2: ...gs on these products and on the engine A Someone should be within range of your voice or close enough to come to your aid when you work near a storage battery B Have plenty of fresh water and soap nea...

Страница 3: ...ber Breakout NRG 22 10 Model Output Output Input Voltage Alarm System Agency Category Voltage Current Frequency Code 12 12 volts 10 10 Amps H 120 208 240V C 5 Alarms L UL S Standard 24 24 volts 50 60...

Страница 4: ...WITH LOCAL ELECTRICAL CODES AND OTHER APPLICABLE INSTALLATION CODES B INSTALLATION MUST BE MADE ACCORDING TO THE INSTALLATION INSTRUCTIONS AND ALL APPLICABLE SAFETY REGULATIONS WARNING ONLY TRAINED A...

Страница 5: ...ected for service remove the output wiring in the reverse of the order given above D Be sure battery terminals are clean and properly tightened Be careful to keep corrosion from coming in contact with...

Страница 6: ...or battery owner s manual and make sure that the 12V 24V select jumper is set to the correct voltage 2 CHARGER LOCATION Do not set a battery or any other object on top of the charger This will obstru...

Страница 7: ...erconnects The above lengths are for operation at 25C For high temperature installations 40C reduce lengths by 10 In the case of high resistance in the cables to the battery the charger may cycle betw...

Страница 8: ...rger by the chassis only Remove the cover only when access is essential for installation and service and replace it promptly when finished B If possible wear an approved static protection strap If one...

Страница 9: ...nch pounds 10 WIRING A All wiring must comply with applicable codes and local ordinances See Section 5 for recommended gauges B The charger contains a DC output fuse for internal fault protection but...

Страница 10: ...KDOWN FIGURE 2A FIGURE 2B E Connect the AC line and neutral conductors at TB1 If there is an identified grounded circuit con ductor neutral attach it to the terminal marked N TB1 will accept 14 6 AWG...

Страница 11: ...K with no AC input TB5 6 FAIL Defaults to Fail with no AC input TB5 9 FAIL Defaults to OK with no AC input TB5 12 FAIL Defaults to OK with no battery TB5 15 FAIL Defaults to fail with no battery RELAY...

Страница 12: ...e 230V position for nominal mains voltages between 208V and 240V B Set the battery range jumper JP1A according to nominal battery voltage Use the 12V position for 12V batteries Use the 24V position fo...

Страница 13: ...SERVICE CONSULT THE BATTERY MANUFACTURER TO DETERMINE IF AND HOW THEY CAN BE SAFELY RESTORED TO SERVICE WARNING NEVER LEAVE A JUMPER IN THE JUMP POSITION DURING NORMAL OPERATION THIS DISABLES THE BATT...

Страница 14: ...onnect AC power then correct the jumper setting or battery voltage before proceeding E After a short delay typically 10 seconds or less the charger will produce output F If the meter display jumper is...

Страница 15: ...a ture increases The output voltage is clamped at 0 and 40 Degrees C to protect against extremely high or low output voltage See chart below Fault Tolerant The charger is protected from the following...

Страница 16: ...short circuit is removed In addition to detecting low battery voltage and short circuits the battery charger also monitors the peak voltage at its DC output terminals and will enter lockout if the DC...

Страница 17: ...On if Temperature Com pensation Working Off if Temperature Compen sation Option not used Confirm if temperature compensation is in tended to be used Only one sensor Local or re mote should be connect...

Страница 18: ...anch circuit breaker and any other disconnect devices 2 The meter display should light immediately after power on The green AC ON LED should be lighted If a temperature sensor is present either intern...

Отзывы: