6.10. FIREBOX
Remove the dust or potential ash
traces that have accumulated
during regular stove operation
twice a week
(see
figure 46a
and
b
). Also it is necessary to
remove and
clean the plate in
the firebox
(see
figure 46c
and
d
). The plate (5) is shown in
figure 2
.
If don’t,
alarm A04
will occur!!!
It is also important to occasionally clean
ash residue between
igniter support tube and igniter
which is located in the firebox within
the burner pot.
It is important to enable free circulation of air around the
igniter, which prevents the igniter from burning out.
Igniter must always be placed in the middle of the supporting tube !