Instruction manual
22
A
B
C
D
E
F
G
H
J
G
J
G
J
J
J
K
L
M
1
2
3
4
1
– Installation of Ø100mm diameter
chimney with space around the pipe
(B):
min 100 mm
, if the pipe is near non-
flammable materials, such as concrete,
brick, and similar
min 300 mm
, if the pipe is near
flammable materials, such as wood and
similar
In both cases, appropriate insulation
between the chimney and the ceiling is
necessary
2
– Existing chimney; minimum smoke
venting pipe diameter Ø 80mm with
external chimney inspection and
cleaning hatch
3
– External chimney made of insulated
stainless steel pipes, Ø80mm minimum
diameter. The entire construction must
be safely installed onto the wall and
must have a protective cap on top (see
chapter 4.5.4.
)
4
– Smoke venting system with T-
pieces enabling easier access when
cleaning the chimney without the
necessity of deconstructing the pipes.
A
– see
figure 15
and chapter
4.5.4.
B
– space around the chimney pipe
C
– minimum 500 mm
D
– maximum 3 m
E
– minimum 50 mm
F
– minimum 3°
G
– insulation
H
– reduction from Ø80 to Ø100 mm
J
– maintenance and cleaning opening
K
– maintenance and cleaning hatch
L
– T-piece with maintenance and
cleaning opening
M
– fresh external air supply grid
Figure 9
M
M
Содержание P 12 SLIM WATER+AIR
Страница 14: ...SENKO pellet WATER AIR stoves Instruction manual 13 Figure 1 P 12 WATER AIR P 12 WATER AIR BOX...
Страница 15: ...SENKO pellet WATER AIR stoves Instruction manual 14 P 12 SLIM WATER AIR P 20 WATER AIR Figure 1...
Страница 17: ...SENKO pellet WATER AIR stoves Instruction manual 16 4 INSTALLATION 4 1 RECOMMENDATIONS Figure 3...