Press the bowl downward until it engages the surface as shown in the fi gure.
Follow these instructions to refi t the tap:
1 suitably lubricate the cap (X) with the supplied Vaseline.
2 introduce the tap spring and body from the lower part of the tap;
3 introduce the lever and fi x it in its seat while keeping the tap body pressed
upwards;
4 introduce the pin (F) without moving the tap lever.
5 reposition the Star gearmotor.
Note: Correctly install the components as shown in the fi gure.
Note: The lack of lubrication of the cap could cause a leakage of
the product from the tap.
7.6. Sanitizing the evaporator
Before starting up the machine, you must sanitize the evaporator.
Proceed as follows:
1 prepare the sanitizing solution in a suitable container (following the direc-
tions provided on the package of the sanitizing product);
2 pour the sanitizing solution into the bowl;
3 allow time for the sanitizing solution to act (see directions on product pack-
age);
4 empty the tank of sanitizing solution by opening the tap.
Then thoroughly rinse the bowl and evaporator to eliminate residues of sanitiz-
ing solution.
Warning: the bowl must be rinsed of sanitizing solution as
directed on the package of the sanitizing product and in ac-
cordance with the hygiene regulations currently in force in the
user’s country.
Fig.40
Fig.41