A2537-002/01 February 2020
6-21
SEMCO Proprietary Information
Figure 6-30 shows the
Low Pass Filter
using the remote GUI. The user clicks on
Advanced Settings
and then the
Low Pass Filter
window to toggle
ON
as shown.
Figure 6-30
Video De-Emphasis and Low Pass Filter Settings on Remote GUI
6.8.5 Modulation Indexing
Applicable to the Trellis FM demodulator format, transmitter deviation is defined as 35% peak deviation.
Modulation Indexing provides for signal acquisition and lock when confronted with transmitter deviation
that is drifting between 30% and 40% peak deviation. When in
Auto
, the receiver compensates for this
drift.
Manual
allows the user to enter a fixed value between 0.3 (30% peak deviation) and 0.4 (40% peak
deviation).
Manual Mod Indexing
is normally used when the transmitter peak deviation is a known and fixed value
between 0.3 and 0.4.
Figure 6-31 shows how to enable either
Auto
or
Manual Modulation Indexing
using the Front Panel
LCDs and Keypad.
For
Auto
Modulation Indexing, the operator pushes the
DEMOD
button to enable the
<
Ch1
> Demod Menu
display, uses the
UP
(2) and
DOWN
(8) arrows to scroll to
T-FM Mod
in blue, and then pushes
ENTER
or
SELECT
(5) to highlight the selection
window in
bright magenta
. The selection window indicates
Auto,
and the operator pushes
ENTER
or
SELECT
(5).
Using the horizontal
LEFT
(4) and
RIGHT
(6) arrows, the operator selects
<
Ch2
>
and pushes
ENTER
or
SELECT
(5) to highlight the selection
window in
bright magenta
. The selection window indicates
Auto
,
and the operator then pushes
ENTER
or
SELECT
(5). The operator repeats these steps for
<
Comb
>
.