A2537-002/01 February 2020
6-11
SEMCO Proprietary Information
Using the remote GUI, the user enables the clock phase pull-down menu by clicking on
Advanced
Settings
as shown in Figure 6-18.
Figure 6-18
Remote GUI Embedded Bit Sync Clock Phase Settings
6.6.3 I/Q Interleaving
I
nterleaving the analog I and Q baseband video outputs for QPSK and UQPSK demodulator formats is
enabled as shown in Figure 6-19.
The operator pushes the
DEMOD MODE
button to access the
<
Ch1
>
Demod Menu
display, uses the
UP
(2) and
DOWN
(8) arrows to scroll to
BS DATA Q/I INTERLEAVING
in blue, and then pushes
ENTER
or
SELECT
(5) to highlight the
selection window in
bright magenta
. Using the
UP
(2) and
DOWN
(8) arrows,
the operator selects
ON
and pushes
ENTER
or
SELECT
(5).
Using the horizontal
LEFT
(4) and
RIGHT
(6) arrows, the operator selects
<
Ch2
>
in the
Demod Menu
header display bar, pushes
ENTER
or
SELECT
(5) to highlight the selection window in
bright magenta
,
uses the
UP
(2) and
DOWN
(8) arrows to select
ON
and then pushes
ENTER
or
SELECT
(5).
Using the horizontal
LEFT
(4) and
RIGHT
(6) arrows again, the operator selects
<
Comb
>
in the
Demod
Menu
header display bar, pushes
ENTER
or
SELECT
(5) to highlight the selection window in
bright
magenta
, uses the
UP
(2) and
DOWN
(8) arrows to select
ON
and then pushes
ENTER
or
SELECT
(5).
Figure 6-19
Front Panel I/Q Interleaving Selection