![Semco RC100C-2 Скачать руководство пользователя страница 64](http://html.mh-extra.com/html/semco/rc100c-2/rc100c-2_user-manual_1237449064.webp)
A2537-002/01 February 2020
6-3
SEMCO Proprietary Information
Figure 6-4 depicts the Demodulator Control Window on the remote GUI. Clicking on the arrow icon to the
right of the
Demod Mode
box provides a pull-down menu for demodulator mode selection. The operator
uses the pull-down menu
Up/Down
arrows to scroll and click on the desired demodulator format
Figure 6-4
Demodulator Mode Selection on Remote GUI
6.3
Demodulator Data Rate Entry
Demodulator Data Rate selection using the front panel displays and controls is shown in Figure 6-5. The
operator selects
DATA RATE
on the keypad, and then uses the numerical keypad to enter the desired
data rate. The data rate will read in kbps and then switch to Mbps for data rate entry above 1.0 Mbps.
The operator pushes
ENTER
or
Select
(5) and the data rate of
Ch1
,
Ch2
and
Combiner
demodulators
are changed.
Figure 6-5
Demodulator Data Rate Selection Using Front Panel Displays and Keypad
Referring to Figure 6-6, the data rate of individual channels can be changed using the same procedures
described above as follows:
A.
Push
DATA RATE
button 2 times -
Ch1
B.
Push
DATA RATE
button 3 times -
Ch2
C.
Push
DATA RATE
button 4 times -
Combiner
Pushing the
DATA RATE
button 5 times exits the menu.
Содержание RC100C-2
Страница 105: ......