38
4 Electrical Installation
4.1 Installation of deck gland and connection box
The connection box makes it easier to disconnect the Furlex from the boat. It is usually placed in
the anchor box. It has sealing inserts prepared for three cables on each side. Position it as high as
possible.
Installation of Furlex Electric above deck
1.
Find a suitable position and direction for the
deck gland.
Feed the cables through the protective hose
and attach the hose to the drive unit tempo-
rarily.
Mark the cutting point on the hose.
Make sure the hose and cables do not
stretch when drive unit moves side to side.
Remove hose and cut it.
Drill a ø20-30mm hole in the deck. Smooth
any sharp edges.
Apply sealant in the groove and fasten the
deck gland using the self-tapping screws
supplied in the kit.
2.
Feed the cables through the hose and
attach the hose to the drive unit with a
hose clamp. Do not over-tighten.
3.
Feed the cables through the deck gland and
attach the hose to the deck gland with a
hose clamp.
Содержание Furlex Electric