Soft start (Quasar...Classic)
Permits adjustment of the wire feed speed in the phases
prior to arc striking.
Given as a % of the wire speed set.
Permits striking at reduced speed, therefore softer and
with less spatter.
Minimum 10%, Maximum 100%, Default 50%
Burn back (Quasar...Classic)
Permits adjustment of the wire burn time, preventing
sticking at the end of welding.
Permits adjustment of the length.
Permits adjustment of the length of the piece of wire
outside the torch.
Minimum -2.00, M2.00, Default syn
3.3 Set up
Permits set up and adjustment of a series of additional parameters
for improved and more accurate control of the welding system.
The parameters present at set up are organised in relation to the
welding process selected and have a numerical code.
Entry to set up:
by pressing the encoder key for 5 sec.
Selection and adjustment of the required parameter:
by
turning the encoder until displaying the numerical code relating
to that parameter. If the encoder key is pressed at this point,
the value set for the parameter selected can be displayed and
adjusted.
Exit from set up:
to quit the "adjustment" section, press the
encoder again.
To exit the set up, go to parameter "O" (save and quit) and press
the encoder.
3.3.1 Quasar...Classic
List of set up parameters (MIG/MAG)
0
Save and quit
Allows you to save the changes and exit the set up.
1
Reset
Allows you to reset all the parameters to the default
values.
3
Wire speed
Allows the regulation of the wire feed rate.
Minimum 0.5 m/min, Maximum 22 m/min, Default
1.0m/min
7 Voltage
Allows the regulation of the arc voltage.
Allows regulation of the arc length during welding.
High voltage = long arc
Low voltage = short arc
Minimum 5V, Maximum 55.5V
10
Pre-gas
Allows you to set and adjust the gas flow prior to striking
of the arc.
Permits filling of the torch with gas and preparation of
the environment for welding.
Minimum off, Maximum 25 sec., Default 0.1 sec.
11
Soft start
Permits adjustment of the wire feed speed in the phases
prior to arc striking.
Given as a % of the wire speed set.
Permits striking at reduced speed, therefore softer and
with less spatter.
Minimum 10%, Maximum 100%, Default 50% (syn)
12
Motor slope
Allows you to set a gradual transition between the
sparking wire speed and the welding wire speed.
Minimum off, Maximum 1.0 sec., Default off
15 Burn
back
Permits adjustment of the wire burn time, preventing
sticking at the end of welding.
Permits adjustment of the length.
Permits adjustment of the length of the piece of wire
outside the torch.
Minimum -2.00, M2.00, Default syn
16 Post-gas
Permits setting and adjustment of the gas flow at the
end of welding.
Minimum off, Maximum 10 sec., Default 2 sec.
30 Spot
welding
Allows you to enable the "spot welding" process and
establish the welding time.
Minimum 0.1s, Maximum 25s, Default off
31 Pause
point
Allows you to enable the "pause point" process and
establish the pause time between one welding opera-
tion and another.
Minimum 0.1s, Maximum 25s, Default off
202 Inductance
Allows electronic regulation of the series inductance of
the welding circuit.
Makes it possible to obtain a quicker or slower arc to
compensate for the welder’s movements and for the
natural welding instability.
Low inductance = reactive arc (more spatter).
High inductance = less reactive arc (less spatter).
Minimum -30, M30, Default syn
500
Reset XE (Easy Mode)
Not used
Reset XA (Advanced Mode)
Manual welding method.
Allows the manual setting and regulation of each indi-
vidual welding parameter.
Reset XP (Professional Mode)
Allows the manual setting and regulation of each indi-
vidual welding parameter.
Makes it possible to use a series of pre-settings available
in the memory of the system.
Allows access to the higher set-up levels:
USER:
user
SERV:
service
SELCO:
Selco
551 Lock/unlock
Allows the locking of the panel controls and the inser-
tion of a protection code (consult the “Lock/unlock”
section).
705
Circuit resistance calibration
Lets you calibrate the system.
Press the encoder knob to access parameter 705.
Place the tip of the wire guide in electrical contact with
the work piece.
Press and hold the torch trigger for at least 1 s.
751 Current
reading
Allow the real value of the welding current to be dis-
played.
Allows the welding current display method to be set.
752 Voltage
reading
Allows the real value of the welding voltage to be dis-
played.
Allows the welding voltage display method to be set.
760
(Motor) Current reading
Allow the real value of the (motor) current to be dis-
played.
Содержание Quasar 320 SMC Classic
Страница 94: ...94...
Страница 253: ...1 1 1 10 C 40 C 14 F 104 F 25 C 55 C 13 F 131 F 50 40 C 40 00 C 90 20 C 68 F 2000 6500 1 2 10 MIG MAG 253...
Страница 254: ...254 1 3 1 4 11 35 1 5...
Страница 255: ...255 1 6 1 7 EN IEC 60974 10 B A A EN60974 10 A pace maker Zmax Ssc Point of Commom Coupling PCC...
Страница 256: ...1 8 IP S IP23S 12 5 mm 60 2 2 1 2 2 10 2 3 400V 15 15 2 1 5 256...
Страница 257: ...257 2 4 MMA 1 2 3 4 MIG MAG MIG MAG 1 2 3 4 4 5 6 5 20...
Страница 268: ...268 5 6 Reset encoder...
Страница 269: ...269...
Страница 270: ...270...
Страница 271: ...271 7 7 1 MMA Hot Start Arc Force antisticking 7 2 MIG MAG MIG...
Страница 272: ...SHORT ARC 1a SHORT a SPRAY ARC b SPRAY ARC 1b 2 3 2 3 272 1a 1b...
Страница 278: ...278 QUASAR 320 SMC Exclusive...
Страница 279: ...279 QUASAR 400 SMC Classic Smart...
Страница 280: ...280 QUASAR 400 SMC Exclusive...
Страница 281: ...281...
Страница 283: ...283 Quasar 400 SMC Classic Smart Quasar 400 SMC Exclusive...
Страница 287: ...287...
Страница 288: ...288 55 15 004 55 15 005 55 15 006 QUASAR 400 SMC CLASSIC QUASAR 400 SMC SMART QUASAR 400 SMC EXCLUSIVE...
Страница 291: ...291...
Страница 295: ...295 73 11 012 Kit Push Pull...
Страница 296: ...296 2X M3 5x9mm...