312
Arc detachment voltage
Allows you to set the voltage value at which the electric
arc switch-off is forced.
It permits improved management of the various oper-
ating conditions that occur. In the spot welding phase,
for example, a low arc detachment voltage reduces
re-striking of the arc when moving the electrode away
from the piece, reducing spatter, burning and oxidisa-
tion of the piece.
If using electrodes that require high voltages, you are
advised to set a high threshold to prevent arc extinction
during welding.
Never set an arc detachment voltage higher than
the no-load voltage of the power source.
Parameter set in Volts (V).
Minimum 0V, Maximum 99.9V, Default 57V
500
Allows the selection of the required graphic interface:
XE (Easy Mode)
XA (Advanced Mode)
XP (Professional Mode)
Allows access to the higher set-up levels:
USER:
user
SERV:
service
SELCO:
Selco
501 Info
Allows the display of a set of information related to the
system.
502 Alarm
queue
Allows the intervention of an alarm to be indicated and
provides the most important indications for the solution
of any problem encountered.
(Consult the “Alarms screen” section).
551 Lock/unlock
Allows the locking of the panel controls and the inser-
tion of a protection code (consult the “Lock/unlock”
section).
552 Buzzer
tone
Permits adjustment of the buzzer tone.
Minimum Off, Maximum 10, Default 5
553 Contrast
Permits adjustment of the display contrast.
Minimum 0, Maximum 50, Default 25
602
CH1, CH2, CH3, CH4 External parameter
Allows the management of external parameter 1 (mini-
mum value, maximum value, default value, parameter
selected).
(Consult the “External controls management” section).
751 Current
reading
Allow the real value of the welding current to be dis-
played.
Allows the welding current display method to be set
(consult the “Interface personalisation” section).
752 Voltage
reading
Allows the real value of the welding voltage to be dis-
played.
Allows the welding voltage display method to be set
(consult the “Interface personalisation” section).
List of set up parameters (TIG)
0
Save and quit
Allows you to save the changes and exit the set up.
1
Reset
Allows you to reset all the parameters to the default
values.
2 Pre-gas
Allows you to set and adjust the gas flow prior to striking
of the arc.
Permits filling of the torch with gas and preparation of
the environment for welding.
Minimum 0.0sec., Maximum 99.9sec., Default 0.1sec.
3 Initial
current
Allows regulation of the weld starting current.
Allows a hotter or cooler welding pool to be obtained
immediately after the arc striking.
Parameter setting: Amperes (A) - Percentage (%).
Minimum 3A-1%, Maximum Imax-500%, Default 50%
5
Initial current time
Allows setting of the time for which the initial current is
maintained.
Parameter setting: seconds (s).
Minimum off, Maximum 99.9s, Default off
6 Slope-up
Allows you to set a gradual passage between the initial
current and the welding current. Parameter set in sec-
onds (s).
Minimum off, Maximum 99.9s, Default off
7 Welding
current
Permits adjustment of the welding current.
Parameter set in Amps (A).
Minimum 3A, Maximum Imax, Default 100A
8 Bilevel
current
Permits adjustment of the secondary current in the
bilevel welding mode.
Parameter set in Amps (A).
Minimum 3A-1%, Maximum Imax-100%, Default 50%
10
Basic current
Permits adjustment of the basic current in pulsed and
fast pulse modes.
Parameter set in Amps (A).
Minimum 3A-1%, Maximum Weld current-100%,
Default 50%
12 Pulsed
frequency
Allows activation of the pulse mode.
Allows regulation of the pulse frequency.
Allows better results to be obtained in the welding of
thin materials and better aesthetic quality of the bead.
Parameter setting: Hertz (Hz) - KiloHertz (kHz).
Minimum 0.1Hz, Maximum 250Hz, Default off
13
Pulsed duty cycle
Allows regulation of the duty cycle in pulse welding.
Allows the peak current to be maintained for a shorter
or longer time.
Parameter setting: percentage (%).
Minimum 1%, Maximum 99%, Default 50%
14
Fast Pulse frequency
Allows regulation of the pulse frequency.
Allows focusing action and better stability of the elec-
tric arc to be obtained.
Parameter setting: KiloHertz (kHz).
Minimum 0.02KHz, Maximum 2.5KHz, Default off
Содержание Genesis 2700 TLH
Страница 42: ...42...
Страница 102: ...102...
Страница 122: ...122...
Страница 162: ...162 162...
Страница 182: ...182...
Страница 202: ...202...
Страница 222: ...222...
Страница 225: ...1 1 1 10 C 40 C 14 F 104 F 25 C 55 C 13 F 131 F 50 40 C 40 00 C 90 20 C 68 F 2000 6500 1 2 10 225...
Страница 226: ...226 1 3 1 4 11 35 1 5 1 6...
Страница 227: ...227 1 7 EN60974 10 A pace maker 1 8 IP S IP23S 12 5 mm 60 2...
Страница 228: ...2 1 2 2 10 2 3 115V 230V 15 15 2 1 5 2 4 MMA TIG 1 o 2 228...
Страница 233: ...233 606 U D CH1 751 752 3 6 1 60 1 2 3 4 5 6 2 4 1 encoder 2 3 encoder encoder 1 2 3 2 1...
Страница 237: ...237 4 3 2 RC 180 4 4 U D U D TIG Set up 5 6...
Страница 238: ...Reset 238...
Страница 239: ...239 7 7 1 MMA...
Страница 245: ...245 11 Schema Diagram Schaltplan Sch ma Esquema Diagrama Schema kopplingsschema Oversigt Skjema Kytkent kaavio...
Страница 247: ...247...
Страница 256: ...256...