EM00136061
rev. 2.5
EN
6
Display during Operation
Display during Setting (MODE key)
Batch
F
F
F
M
M
M
7.0ml
Lev
Stop
0
Operating mode
Batch
Alarms and statuses
Lev = Level alarm
Flw = Flow alarm
Mem = Memory alarm
FLOW
sensor
status
Programmed value
Quantity in ml
Pump status
Empty = pump in start
Stop = pump stationary
Paus = pump in pause
Current dosage value
Gradually displays
the dosed quantity
Memory
function
status
Q.ty
7.0ml
7.0ml
Operating mode
Displays in sequence: quantity to
be dosed, dosage time and pump
frequency
Dosage value
The quantity can be modified by pressing the
+ or – keys at the same time
Paragraph 7 – Proportional to External Impulses (ppm dosage)
Programming
Operation
+
-
-
-
-
+
-
+
-
+
-
+
-
+
-
+
-
Pump Funtions
Configuration
Pump Functions
ppm Mode
ppm
50
Pulse/l
4
Pulse/L
4
L/pulse
4
Conc(%)
100
Memory
Off
PROG
ppm Mode
ppm Mode
ppm Mode
ppm Mode
ppm Mode
ppm Mode
-
The pump doses in proportion to an external signal (i.e.:
impulse
launch
counter),
automatically
calculating
the
relationship between incoming signals and pump strokes on
the basis of the programmed ppm value.
The data to be entered is the ppm value, the impulse/litre
ratio (or litre/impulse) of the counter and the concentration of
the product to be dosed.
The dosage frequency can be modified during operation, by
pressing the
keys at the same time to increase
the flow, or the
keys to decrease it.
Display during Operation
Display during Setting (MODE key)
Ppm
F
F
F
M
M
M
10
Lev
Stop
F300s/m
Operating mode
ppm
Alarms and statuses
Lev = Level alarm
Flw = Flow alarm
Mem = Memory alarm
FLOW
sensor
status
Programmed ppm
value
Pump status
Empty = pump in start
Stop = pump stationary
Paus = pump in pause
Current dosage value
Frequency
Memory
function
status
cc/stroke
1.0
0.23
F300s/m
Operating mode
Displays in sequence: cc/stroke,
impulses/minute on the counter and %
concentration of the chemical product
Dosage value
Programmed
ppm value
The dosage frequency value can be
modified by pressing the + or – keys
at the same time.