EM00136061
rev. 2.5
EN
11
Paragraph 17 - Setting the Pause
Programming
Operation
-
-
Paus
N.Open
PROG
+
-
Configuration
+
The pump can be paused by remote input.
The factory setting is Normally Open.
Changes can be made by pressing the
key, then
using the
keys to set the new value ( N. OPEN or
N. CLOSED).
Press
to confirm and return to the main menu.
Display contrast adjustment.
For adjusting the display contrast keep the key
pressed and within 5 seconds press the keys
or
to
increase or decrease the contrast.
Alarms
Display
Cause
Interruption
Fixed alarm LED
Flashing word “Lev”
End
of
level
alarm,
without
interrupting pump operation
Restore the liquid level.
I.e.
Man
Lev
P100%
Fixed alarm LED
Flashing words “Lev” and “stop”
End of level alarm, with interruption
to pump operation
Restore the liquid level.
I.e.
Man
Lev
Stop
P100%
Flashing word “Mem”
The pump receives one or more
pulses during dosage with memory
function on Off
Press the
key
I.e.
1:n
6
Mem
Flashing word “Mem”
The pump receives one or more
pulses during dosage with memory
function on On
When the pump finishes receiving
external impulses, it returns the
memorized strokes
I.e.
1:n
M
6
Mem
Fixed alarm LED
Flashing word “Flw”
Active flow alarm. The pump has
not
received
the
programmed
number of signals from the flow
sensor.
Press the
key
I.e.
Man
F
Flw
P100%
Internal CPU communication error.
Press the
key to restore the
default parameters.
I.e.
Parameter Error
PROG to default