EM00136061
rev. 2.5
EN
8
Paragraph 8 – Timed Dosage
(Frequency signal input “TRIGGER” not activated)
Programming
Operation
+
-
-
-
-
+
-
+
-
+
-
Tempo
Quantity
100ml
Delay
0.01.50
Interval
0.01.50
PROG
Time
Time
g.hh.mm
Time
g.hh.mm
Configuration
Pum functions
Configuration
Pum functions
-
-
Trigger Mode
Pause Input Mode
Disable
Restart Timer
+
-
-
Pause Input Mode
Restart Timer
-
Pause Input Mode
Freeze Time
Pause Input Mode
Pause Dosing
The pump doses a programmed quantity in ml. It is possible to set a
pump delay time (
Delay
) when the pump is started and an interval
between two successive dosings (
Interval
), as illustrated in the
diagram:
The
Delay
and
Interval
times are in dd.hh.mm (days, hours,
minutes)
The
Pause
input can be programmed in three different modes:
1.
FreezeTime:
when the pause is activated, the system cuts
out the current time count and restarts it when the pause is
deactivated.
2.
Pause Dosing:
with the pause activated, the system
continues to count time the and stops the dosing.
3.
Restart Timer
: when the pause is activated, the system
stops the dosing and when the pause is deactivated the
count starts again from the beginning.
The dosage frequency can be modified while the pump is operating,
by pressing the
keys at the same time to increase the
frequency, or the
keys to decrease it.
Display during Operation
Display at start-up (MODE key)
Timer
F
F
F
7.0 ml
Liv
Stop
P 0%
Operating mode
Timer
Alarms and Level
statuses = level alarm
Flow = flow alarm
FLOW
sensor
status
Programmed value
Quantity in ml
Pump status
Dry = pump starting up
Stop = pump stopping
Restart = pump restarting
Value of dosing in
progress:
Percentage of
strokes/min max
Q.tà
20,0ml
20,0ml
P 100%
Operating mode
The following are shown in sequence:
quantity to dose, delay in d.hh.mm.
and interval in d.hh.mm
Dosing value
Programmed
quantity in m
l
Value of the dosing percentage,
which can be modified by
pressing the + or – keys
Paragraph 9 – Setting the Maximum Flow
Programming
Operation
-
-
-
Pump Functions
Max flow rate
Max flow rate
Max flow rate
P100%
P100%
F320s/m
PROG
-
+
-
+
-
This makes it possible to set the maximum flow offered by
the pump, and the programmed mode (% or frequency) is
used as the standard unit of measurement when displaying
the flow. Changes can be made by pressing the
key,
then using the
keys to set the new value. Press
to confirm and return to the main menu
Delay
Interv.
Quantity