EM00136061
rev. 2.5
EN
9
Paragraph 10 – Setting the Alarm Relay
Programming
Operation
-
-
-
-
Pump Functions
Max flow rate
Alarm Relay
P100%
N.Open
PROG
+
-
In the absence of an alarm situation, it can be set as open
(default) or closed.
Changes can be made by pressing the
key, then using
the
keys to set the new value. Press
to
confirm and return to the main menu
Paragraph 11 – Flow Calibration
Programming
Operation
-
-
-
Pump Calibration
Pump Calibration
Automatic Cal.
Automatic Cal.
Automatic Cal.
Pump Calibration
0,23 cc/stroke
cc/stroke
0,23
Start 100 strok.
Strokes
100
ml
20
Manual
PROG
+
-
+
-
Pump Calibration
Automatic
-
The memorized cc value per strike appears in the main
menu. It can be calibrated in two different ways:
MANUAL – manually enter the cc value per strike using the
keys and confirm by pressing the
key
AUTOMATIC – the pump makes 100 strikes, which are
started by pressing the
key. At the end of this process,
enter the quantity sucked up by the pump using the
keys and confirm by pressing the
key.
The entered figure will be used in flow calculations.
Paragraph 12 - Statistics
Programming
Operation
The main menu displays the pump operation times. By
pressing the
key you can access other statistics:
- Strokes = number of strokes made by the pump
- Q.ty (L) = quantity dosed by the pump in litres; this figure is
calculated on the basis of the memorised cc/stroke value
- Power = number of pump starts
- Reset = use the
to reset the counters (YES) or
otherwise (NO), then confirm by pressing the
key.
Pressing the
key will take you back to the main menu.