EM00136061
rev. 2.5
EN
3
Setting the Language
Programming
Operation
-
-
-
-
-
Pump Functions
Max flow rate
Alarm Relay
Language
P100%
N.Open
English
PROG
+
-
Makes it possible to select the language. The pump is set in
English in the factory.
Changes can be made by pressing the
key, then
using the
keys to set the new value. Press
to
confirm and return to the main menu
Paragraph 1 – Manual Dosage
Programming
Operation
+
-
Pump Funtions
Configuration
Pump Functions
PROG
The pump operates in constant mode. The flow can only be manually
regulated by pressing the
keys at the same time to increase
the flow, or the
keys to decrease it.
Display during Operation
Display during Setting (MODE key)
MAN
F
F
F
Lev
Stop
P100%
Operating mode
Man = Manual
Alarms and statuses
Lev = Level alarm
Flw = Flow alarms
FLOW sensor
status
Pump status
Empty = pump in start
Stop = pump stationary
Paus = pump in pause
Current dosage speed
(depends on selected unit of
measurement)
Percentage, Frequency,
l/h, Gph, ml/m
MAN
P100%
Operating mode
Man (during manual modification of the
flow it displays the corresponding
frequency value)
Current dosage value
Modify the maximum flow by pressing the
+ or – keys at the same time
Paragraph 2 - Dosage Proportional to Signal 0/4-20
Programming
Operation
+
-
-
-
+
-
+
-
Pump Funtions
Configuration
Pump Functions
0/4 - 20 mA
0/4 - 20 mA
0/4 - 20 mA
Low
4.0mA
High
20.0mA
PROG
The pump proportionally doses at a signal of (0)4-20 mA. On the basis of
the factory settings, the pump interrupts dosage at 4mA and doses at the
maximum set frequency when it receives 20 mA. These two values can be
modified during programming. The maximum frequency can be modified
during operation, by pressing the
keys at the same time to
increase the flow, or the
keys to decrease it.