EXPLANA
TION OF TEST
AND DA
TA
DISPLA
Y
CALIBRATION SETTING MENU
INPUT GAS PEDAL VALUE ***
MINIMUM GAS ***
SETTING HANDLE LEFT
-> SETTING CONTENTS MINIMUM GAS
RIGHT
LEFT
EXIT
SELECT WITH SERVICE AND PRESS TEST
This screen allows you to adjust the minimum values for the left and right gas pedals.
Move the cursor to SETTING CONTENTS, and select MINIMUM GAS with the TEST Button.
INPUT GAS PEDAL VALUE:
Stepping on the gas pedal will move the ▼ to the left or right, displaying the actual gas pedal input value.
MINIMUM GAS:
As shown on the screen, set the ▲ to the right of the ▼, which represents the point when pressure is no longer
applied to the gas pedal. The leftmost ▲ represents the value where the gas will actually begin functioning.
The leftmost ▲ can be moved to the right or left with RIGHT or LEFT.
FIG. 3-3fd Calibration Setting Menu Minimum Gas Screen