ERROR DISPLA
Y
ACTUATOR LR CW LIMIT OVER
The left and right sides’ actuators’ lower limit switches have not been properly installed or have broken down.
An error will occur when the limit switches are not turned ON.
Adjust or replace the limit switches.
ACTUATOR LR CCW LIMIT OVER
The left and right sides’ actuators’ upper limit switches have not been properly installed or have broken down.
An error will occur when the limit switches are not turned ON.
Adjust or replace the limit switches.
ACTUATOR TIME OUT ERROR
Ride initialization did not properly complete or did not occur.
Check the wiring connections from the LINDBERGH to the actuator control board, and from the actuator control
board to the servo amplifier.
Confirm that there is power to the actuator control board and to the servo amplifier.
The actuator control board is found when the motor driver door at the right side of the cockpit is removed.
FIG. 5b Actuator Control Board
Содержание OUTRUN 2 SPECIAL TOURS SDX