9.0 Maintenance
Page 9.20
Maintenance for 548.10 G \ 05.2007 \
Caution, Danger for your life
In the system there are some parts with mains power. By
mainte nance and ser vice pro ce du res turn the entire
system off, shut off from mains by re mo ving the mains
plug. There is danger for your life.
Danger of burns
Start working after the system is cooled down.
1.
Turn the entired system off, shut off from mains by
removing the mains plug.
2.
First let the machine cool down before you start wor-
king in the machine.
3.
Dismount the complete grid belt transport system
descripted in the section "Dismounting and Mounting
of the grid belt transport system".
4.
At the transport system an angled bracket with a
photocell is mounted. The leads of the photocell are
connected to a plug. Do yet remove the connector.
5.
Unscrew and remove the screws from the angled
bracket of the photocell.
6.
Remove the defective photocell.
7.
Replace the new photocell in the bracket. Fasten with
the screws.
8.
Place the connector of the new photocell into the
plug.
9.
Mount the complete grid belt transport system de-
scripted in the section "Dismounting and Mounting of
the grid belt transport system".
10.
Connect the unit to the power supply again and
switch it on.
Dismounting and
mounting of the
transport control