NOTE 1:
Unit should only be connected to a fire alarm panel when
used in a FSA configuration.
NOTE 2:
If the DIP switch for FAI latching is set to the “Latched”
Position, the LOCK output and the red LED will remain in fire
alarm state even when an active FAI input is removed. The
user will need to depress the reset button on the bottom right
of the front panel for 1 second (see Figure 1, “Reset Button
and LED Locations”) to reset the fire alarm state (red LED off
and lock per access control input). The factory default DIP
switch settings are as follows:
DIP Switch Name
Default Position
Notes
Access control input Normally Open (NO) Normally Closed (NC)
FAI input
NO
NC
FAI Latch
FAI Latching Disabled FAI Latching Enabled
Lock Type
Fail-Safe (FSA)
Fail-Secure (FSE)
Figure 1: Reset Button and LED Locations