8
500-33530, Rev B
Status Signaling
Green LED Signaling
AC Power Mode: Solid on
AC Standby Mode: 2s on / 2s off
AC Lost Mode: 1s on / 2s off
Output Voltage Abnormal: OFF
Battery Disconnected: Rapid flash (4 times per
second, then off for 1 second)
NOTE:
Black text indicates condition; green text
indicates corresponding LED lighting pattern.
Red LED Signaling
Power Supply Alarm Mode: ON
Power Supply Normal Mode: OFF
Output Voltage Abnormal: Blink at 1 Hz
Battery Discharged Below 9.6V: Blink at0.5 Hz
NOTE:
If alarm has occurred and FAI set to
latch mode, power supply stays in alarm mode
until the reset button on the front panel is
pressed.
Buzzer
Beep at 1/3 Hz for 30 seconds every 15 minutes
NOTE:
Reset battery by pressing the reset
button on front panel for 5 seconds to silence
alarm for 24 hours.
Access Control and FAI Operations
The following table describes how the lock power output (DC2) responds
to the access control input under various DIP switch settings. This table
is only valid when the EcoPower has not received a fire alarm activation
signal at the FAI input.
Access Control
Input
DIP Switch Settings
Output
Access Dry
Contact State
Access DIP
Switch
Setting
Lock Type DIP
Switch Setting
LOCK
Output
Voltage
FAI LED
(RED)
Open NO
Fail-Safe
(FSA)
On
Off
Open NO
Fail-Secure
(FSE)
Off
Off