16
500-33530, Rev B
4. ATTACH appropriate drywall anchors (one example shown).
5. MOUNT enclosure box to drywall using the screws to attach it to the
drywall anchors.
NOTE:
It is recommended that the conduit be installed on the top and
bottom of the enclosure box for wiring and the battery be
installed horizontally.
6. ENSURE wire conduit is connected to the enclosure with strain relief.
NOTE 1:
The battery may be oriented in the junction box either vertically
or horizontally as long as the connection wires from the battery
and power supply module have a clear pathway to the
attached wire conduits.
NOTE 2:
If the included battery/battery-type is not used, fish paper must
be used to provide insulation for the installed battery.
7. INSTALL the battery into the junction box.
8. (Optional) REMOVE the power supply module from the cover to
ease in connection of wiring.
NOTE:
Wiring must be Class 1.
9. CONNECT the access control device, access control panel, fire
alarm interface, battery, and lock wiring to the power supply module
terminals.