Output Voltage Ripple and Noise 

< 0.14 Vpp (20 MHz bandwidth  

 limit 

measurement) 

Output Surge Resistance 

2400 Vpk 

Output Over Voltage Protection 

Under any single point  

 

condition, output voltage shall  

 

not exceed 120% of nominal  

 voltage 
Battery Type and Capacity 

Sealed Lead Acid (SLA), 12V,  

 0.8 

Ah 

Battery Standby Time 

20.5 hours dependent on lock  

 

type (FSA or FSE) and usage.   

 

Battery standby time is  

 

designed for EcoFlex lock with  

 

optional H1 controller only (not  

 

for 100 mA load).  H1 controller  

 

draws an average of 5 mA.   

 

The two total current draw is  

 

about 20 mA. 

 

Total Load Current

0.8 Ah Battery Backup Time

20 mA 

20.5 hours 

50 mA 

6.5 hours 

100 mA 

2 hours 

 
 

 

Regulatory Certifications 

 

UL294

, "Access Control System Unit," 6th Edition 

 

UL603

, "Power supply for use with Burglar Alarm System," 5th 

Edition 

 

CAN/ULC-S533

, "Egress Door Securing and Releasing Devices," 

3rd Edition 

 

GreenCircle Certified 

(99% Energy Savings) 

NOTE:

 

50% - battery discharge time from fully charged 
condition. 

Содержание EcoPower EPS-05

Страница 1: ...1 500 33530 Rev B EcoPower Power Supply Owner s Manual...

Страница 2: ...enclosure box flush with the wall stud and wall surface 11 Install the EcoPower Power Supply using the included enclosure box and surface mounted 15 Install the EcoPower Power Supply flush with the st...

Страница 3: ...3 500 33530 Rev B Models EPS 05 EcoPower Power Supply in Enclosure EPS 05B EcoPower Power Supply PCB only Structure...

Страница 4: ...m Specifications Environmental Parameter Value Operating Ambient Temperature 0 to 49 Celsius C Design Product Life 10 years 49 C ambient continuous full load Storage Temperature 25 to 85 C Operating H...

Страница 5: ...02A minimum Hi Pot Test 2500 VAC or 3535 VDC Leakage Current 0 5 mA Output Voltage at No Load Set to 14 0 VDC 0 2 Number of Outputs Two 2 Outputs DC1 Reader 12 VDC nominal 9 4 14 6 VDC for compatibil...

Страница 6: ...attery standby time is designed for EcoFlex lock with optional H1 controller only not for 100 mA load H1 controller draws an average of 5 mA The two total current draw is about 20 mA Total Load Curren...

Страница 7: ...00 3 3 2008 CE LVD and EMC directives currently in effect EU RoHS Directive EU REACH Regulation UL294 Access Control Performance Levels for Model EPS 05 Power Supply NOTE Without an attack resistant e...

Страница 8: ...wer supply stays in alarm mode until the reset button on the front panel is pressed Buzzer Beep at 1 3 Hz for 30 seconds every 15 minutes NOTE Reset battery by pressing the reset button on front panel...

Страница 9: ...rdware shall be used to allow emergency exit from the protected area The following table describes lock power output behavior when there is an active fire alarm signal at the FAI input This ensures th...

Страница 10: ...eed to depress the reset button on the bottom right of the front panel for 1 second see Figure 1 Reset Button and LED Locations to reset the fire alarm state red LED off and lock per access control in...

Страница 11: ...junction box flush with the wall stud or the included enclosure box flush with the wall stud and drywall surface or an enclosure surface mounted on the wall Install the EcoPower Power Supply using the...

Страница 12: ...icky shims on the side of the enclosure to be mounted to the stud NOTE Drilling two small pilot holes approximately 1 16 for the included mounting screws eases installation 4 MOUNT enclosure to stud u...

Страница 13: ...13 500 33530 Rev B 5 PEEL off the backing for the double stick tape on the back of the dress ring and PUSH the dress ring onto the enclosure...

Страница 14: ...g as the connection wires from the battery and power supply module have a clear pathway to the attached wire conduits NOTE 2 If the included battery battery type is not used fish paper must be used to...

Страница 15: ...ons so continuity is maintained 13 MOUNT the cover to the enclosure using the two captive screws Install the EcoPower Power Supply using the included enclosure box and surface mounted 1 DETERMINE loca...

Страница 16: ...nted in the junction box either vertically or horizontally as long as the connection wires from the battery and power supply module have a clear pathway to the attached wire conduits NOTE 2 If the inc...

Страница 17: ...d 12 MOUNT the cover to the junction box using the two captive screws Install the EcoPower Power Supply flush with the stud in an existing 2 gang junction box NOTE Due to the location of the conduit k...

Страница 18: ...nnected to the junction box with strain relief NOTE 1 The battery may be oriented in the junction box either vertically or horizontally as long as the connection wires from the battery and power suppl...

Страница 19: ...power supply module terminals 8 Optional INSTALL the power supply module back into the cover ensuring the LEDs are facing out at the top right and SECURE with the two installation screws 9 CONNECT AC...

Страница 20: ...0 33530 Rev B Securitron Phoenix AZ Tel 1 800 624 5625 Mon Fri 6 00am 4 00pm PDT Fax 1 800 232 7329 www securitron com techsupport securitron com 2015 Hanchett Entry Systems Inc an ASSA ABLOY Group Co...

Отзывы: