MAN_Easyflex_com_eng_01.doc
37
3.8.6
Mode NEXT
Mode NEXT (Near End cross (X) Talk) is for measuring the cross-talk
coupling k1 between two pairs of conductors. Unwanted crosstalk coupling
occurs in particular when wires have been crossed.
The
Easyflex Com
is able to pinpoint the fault precisely, so the fault can
subsequently be eliminated to the point. For instance, the device can
determine the beginning and the end of a ”split pairs” section in a longer
trunk line which is composed of a number of sections.
The point of crosstalk coupling is located as in any normal reflection test.
This mode is different, however, in that the pair which shall carry the
transmitter pulse is connected to L2 and the pair tested for crosstalk to L1.
Press key Line and use the rotary encoder to enable mode NEXT.
Fig. 11
„Split-Pairs“section
Section of line
pair 2
pair 1
L2
L1
Transmission reception
Easyflex Com
Reversed wires
crosstalk