MAN_Easyflex_com_eng_01.doc
15
2.2
Specifications
Modes of testing:
L1:
Reflection test of cable connected to
socket L1 versus built-in balancing
network
L2:
Reflection test of cable connected to
socket L2 versus built-in balancing
network
Alt:
A reflection test is carried out alternately on
cables connected to sockets L1 / L2
Diff:
Measurement
of
difference
between
cables connected to sockets L1 and L2
NEXT:
Location of crosstalk between cables
connected to sockets L1 and L2
Pairs to be connected:
2
Modes of operation:
Single
Cont
Average
Single test
Continuous testing
Averaging of up to 256 test results
Measuring ranges at
v
/
2
= 100 m/µs
50, 100, 200, 400, 1000, 2000 m
4, 15
km
Zoom factors (X direction)
1, 2, 5, 10 (depending on range of
measurement)