16
MAN_Easyflex_com_eng_01.doc
Maximum resolution
1.25 cm for range 50 m at 50 m/µs
2.5 cm for range 50 m at 100 m/µs
2.5 cm for range 100 m
5 cm
for range 200 m
10 cm for range 400 m
25 cm for range 1000 m
50 cm for range 2000 m
1 m
for range 4000 m
2.5 m for range 7500 m
5 m
for range 15 km
Accuracy
± 0.1% of range of measurement
±
1
cursor step
Gain
0 … 80 dB in steps of 1 dB
Dynamic range
90 dB
Distance reading
m, ft, or µs
Setting range of signal
propagation velocity
NVP
v
/
2
0.200 … 0.999 in steps of 0.001
30.0 … 149.9 m/
µ
s or
98.4 … 491.8 ft/
µ
s
Pulse amplitude
5 ns
2 V
±
25 % at 120
Ω
10 ns 2 V
±
25 % at 120
Ω
20 ns 2 V
±
25 % at 120
Ω
50 ns 3,5 V
−
25 % at 120
Ω
200 ns 5,0 V
−
25 % at 120
Ω
750 ns 6,0 V
−
25 % at 120
Ω
Содержание Easyflex Com
Страница 2: ...2 MAN_Easyflex_com_eng_01 doc...
Страница 3: ...MAN_Easyflex_com_eng_01 doc 3 Easyflex Com compact and light weight Time Domain Reflectometer...
Страница 4: ...4 MAN_Easyflex_com_eng_01 doc...
Страница 8: ...8 MAN_Easyflex_com_eng_01 doc...