INSTALLATION
MANUAL
Product:
Document #:
Rev:
Page:
SEAKEEPER 26 / 20HD
90265
7
4 of 13
Section 2: ELECTRICAL INSTALLATION
3. DRIVE BOX AC POWER OUTPUT TO SEAWATER PUMP CONNECTION
INSTRUCTIONS
a. Cable: 3 x 14AWG (3 x 2.0mm
2
CSA) cable, 10’ (3m) length, Seakeeper supplied
pre-installed.
b. Pumps rated at 230 VAC, 5 Amps max., Customer-supplied.
i. Locate CABLE 5 for AC power output to the Seawater Pump from the Drive Box
at the middle of three cable glands. (See Figure 2.)
FIGURE 4
– CABLE 5, AC OUTPUT POWER CABLE
ii. Connect the 230 VAC wires in CABLE 5 to a 5 Amp maximum, Seawater
Pump (approximately 1/3 horsepower or 250 W) according to Figures 4 and 5.
FIGURE 5
– CABLE 5, WIRE CONNECTIONS TO SEAWATER PUMP
c. If the customer-supplied Seawater Pump is not rated for 230 VAC, the CABLE 5
output may be used to switch a customer-supplied relay.
Verify that AC power is OFF to the Drive Box before connecting
CABLE 5 to a Seawater Pump.