Revision 22 13.10
40
for overnight to insure it completely defrosts. Be prepared in case the defrost water pan overflows on the floor.
You may need to set some towels around and under the machine to catch any overflow. After the machine is
thawed completely out you will want to check the temperature settings to insure they are not set too cold. You
may also enter the Advanced menu and check the defrost settings. The standard defrost settings are for a
duration (DUR) of 25 minutes and interval (INT) of 3 hours. This can be changed if need be. Also close the
door and listen to hear if the fans start when you close the door. If they don’t this will also cause a freeze over.
You may need to adjust the door switch to facilitate proper operation.
4. Check the upper door switch. The easiest test is to close the door then while opening the door watch the
display to see if you see the message Sales Value $xxxx.xx in the display. If you do not then suspect the
upper door switch may need adjustment. You can reach over the door and press it manually while watching
the display to see if it works.
5. As a manual test of the cooling system you can enter the Diagnostics section of the menu and select the
Relays test function. Select Relay 02, press F and the cooling system should turn on momentarily.
Ambient Cabinet Assembly
CAUTIONS
:
1. High voltage is located in the area of the unit and could cause injury or death.
2.
Replacement of the bill acceptor, coin changer, front panel display, system control board or
vend motors should only be performed by trained personnel with power disconnected from the
vending machine.