Страница 1: ...er Manual Models 124 125 Catalogues Safety Instruction 2 Product Spec color 3 Product packing list 4 Inspection 5 Operation manual 5 Daily maintains procedure 10 General faults judgment 11 Warranty card 12 Mobile APP installation 14 ...

Страница 2: ...ipe is wrongly connected please adjust on time This product has self priming function but there should don t have air inside of the pump Also the water faucet connection will be your first choice The spare parts of the fog machine including water filter pipe nozzle and so on must use the original parts Otherwise it s very easy to have water leakages oil leakages and other problems When cleaning th...

Страница 3: ...forbidden to open any pump machine inner pipes wire machine valve and other related parts when the machine is running Product Specification and color Detail specification Code Flow Pump Power Max Pressure Rpm Cooling size 3 pistons 70Bar 1000Psi 1300 50Hz 1550 60Hz 124 1 0L min 180W 5M2 65M2 125 1 5L min 180W 5M2 100M2 Nozzles related quantity and size suggestions Size of nozzle 0 10mm 0 15mm 0 20...

Страница 4: ... reminder system 1 Inlet pipe system High level water filter SS304 filter 1 Polyether pipe with faucet connector 1 5m Polyether pipe with machine connector 1 5m Water filter connector already assembled 2 Outlet pressure pipe system 1 4 system PA12 pipe double quality than PA6 11 On customer demand or depend on the models Top level nozzles 0 15mm New quick fitting End quick fitting L type connector...

Страница 5: ...f the package Make sure the product model is correct Make sure the product color is correct Make sure the parts is same according to the packing list During running of the machine Make sure the machine body and parts is no damage Make sure the power wire is no damage Make sure the water filter and nozzle is without any block Make sure the assembly and connection is correct Operation manual Step 1 ...

Страница 6: ...cording to your lay out design Warning 1 The connection pipe to the main machine must be soft to avoid any shaking while the left pipe can use PA PE or SS pipe as customer want 2 Maybe the L type Tee type fitting is required according to your lay out design customer have to design by himself 3 The Nozzle quantity should less than the Max quantity suggestion ...

Страница 7: ...7 Layout example Type A Square rectangle area Type B Triangle area Type C Straight area PA12 pipe PA12 pipe PA12 pipe ...

Страница 8: ...e 5W 30 car engine oil for hot weather Step 4 Connector the inlet pipe to the faucet machine Push the air out of the pump for 10 15 seconds Step 5 Connector the inlet outlet pipe to the machine Fill the oil here Oil drain outlet Or SS pipe ...

Страница 9: ...ine working The faucet just open 1 3 1 2 Please don t open to max because the machine just need a little water Step 7 Set the machine working pressure Usually no need adjustment the machine already done by the factory Please adjust the pressure regulating valve and make the machine working pressure between 4Mpa to 7Mpa The best working is at 5Mpa to 6Mpa Step 8 APP operation system as optional Cha...

Страница 10: ... change oil lamp will automatically on please change the oil and then touch this key for 5 seconds the lamp will off 4 Nonstop Spraying Means machine will spray without any stop for 24 hours 5 App Mode Only when you choose this mode the machine will follow your current mobile setting 6 Change oil This lamp will automatically on after running 300 hours it remind you to change the pump oil the lamp ...

Страница 11: ...W 30 for hot weather Running after 100 hours first formal maintenance Clean and wash the water filter Take out the High pressure pipe connection open the faucet valve and let the faucet water wash the inside of the pump Check the pump working pressure Change the bad nozzles Modified or change the bad quick fitting PA pipe Clean the machine ABS cover with non corrosive safety solvent to protect the...

Страница 12: ...ity 2 Some connectors are leaking Solution check the leaking place change the parts or repair 3 The water filter is blocked and need to be cleaned 4 The seal of the pump is bad and need to change 5 The spring of one way valve is fatigability breakage and need to change a new one Some of the nozzles can t spray the mist The nozzles is blocked and need to clean or change a new one The APP is not wor...

Страница 13: ... invoice is missed has hand modification or unclear 7 Other faults even not because of product quality problem 8 Warranty is for quantity order more than 20 sets from the producer to the dealer 1 year since B L data while dealer must offer warranty to the end user even sales as retail Warranty processing Please contact us at contact efydis fr or at 33 951 634 467 APP operation process Connect mach...

Страница 14: ... old or cheap type may not able for the connection and not stable The better phone the higher speed of connection and the more stable 2 One machine only can connect with one phone if customer need to connect to the other phone the previous phone connection must be disconnected first 3 If the phone can t find the machine code please try the above APP operation process again ...