Revision 22 13.10
37
ERROR CODES
Motor Diagnostic Errors:
01
-
Motor did not Home
02
- Reserved
03
-
Motor is Stuck at Home
04
-
Reserved
05
-
Low Current (Motor did not move)
06
-
Over Current (Hard Error)
07
-
Motor
not
detected
Machine Error Codes:
01 – 80 -
Motor fault from Selection A1 to Selection H10
100 -
Coin Changer not connected
110 -
Bill Validator not connected
120 -
Card Reader 1 not connected
121 -
Card Reader 2 not connected (not used)
130 -
Audit Device not connected
140 -
DEX
Error
150 000 -
Satellite 1 not connected (not used)
150 001 -
Satellite 2 not connected (not used)
150 002 -
Satellite 3 not connected (not used)
160 000 -
Overall Credit value is negative
(Negative credit giving a large credit amount that can be dispensed as change)
160 001 -
Coin Credit was negative
160 002 -
Bill Credit was negative
160 003 -
Bill Return MDB message (value of Bills in escrow exceeds the Bill credit)
160 004 -
Price - Credit when starting a vend
160 005 -
Amount returned when Cancelling/Returning credit in Multivend exceeded credit
160 006 -
Out Of Change when Cancelling/Returning credit in Multivend
160 007 -
Change value is negative after stacking bill
160 008 -
Amount returned as change in single vend mode exceeded credit
160 009 -
Out of Change when giving change in single vend mode
170 001 -
Temperature Sensor Error Zone 1 (not used)
170 002 -
Temperature Sensor Error Zone 2
201
-
Periodic
Lockout
202 -
Health & Safety Lockout
See the Diagnostics Menu information in this manual for more on viewing the error log and clearing errors.