TRANSFORMER
3,6A blow fuse on 230V ~ power supply
6,3A blow fuse on 115V ~ power supply
Power input
Input for the connection of
the electric power.
P = PHASE
N = NEUTRAL
G = GROUND
NOTICE:
for the
connection to the
electric power see
the law in force
Sensor barriers
This control unit comes with a detection device of motor current absorbtion which allows to reveal possible
obstacles during the opening and the closing of the gate. When this device intervenes in opening it causes
the inversion of the movement for around a second, if it intervenes in closing it causes the total reopening
Limit switch
The limit switch can be connected through the special LIMIT SWITCH
connector on the control unit. The control unit can administrate
mechanical, inductive and magnetic limit switches. Only on some special
applications il will not be necessary to connect the limit switches. The
control unit will automatically realize if limit switches are present or not.
Through the on-board display or through the JOLLY 3 programmer it is
possible to activate the ani-intrusion function. This function is lied to the
presence of at least one limit switch which, when free, forces the motor to
re-close.
LIMIT SWITCH AND
SENSOR BARRIERS
Limit
Switch
CN2
Note1:
The sensitivity is adjustable both in opening and in closing through the
on-board display or through the JOLLY 3 terminal. With high torque the gate
reverses after 5 seconds.
Attention:
In case of obstacle, if the automatic reclosing is on, the gate will
attempt to close for 3 times, whereupon a start signal will be necessary to re-
establish the movment.
Note:
if during programming phase the motor and limit switch times should not be in phase between them,
the gate will start in closing, it stops and will not complete the selflearning of the times, at this point it will be
necessary to switch off the tension and to invert the cables of the motor. The first movement in selflearning
must always be executed in closing.
ATTENTION:
When using SEA magnetic limit switches, make sure that the motor is set on
“Magnetic”
present in the special menu 104-SELECT LIMIT SWITCH.
MOTOR POWER SUPPLY