background image

TERMS OF SALES

EFFICACY OF THE FOLLOWING TERMS OF SALE:

 the following general terms of sale shall be applied to all orders sent to SEA S.p.A. 

All sales made by SEA to all costumers are made under the prescription of this terms of sales which are integral part of sale contract and 
cancel and substitute all apposed clauses or specific negotiations present in order document received from the buyer.

GENERAL  NOTICE 

The  systems  must  be  assembled  exclusively  with  SEA  components,  unless  specific  agreements  apply.  Non-

compliance  with  the  applicable  safety  standards  (European  Standards  EM12453  –  EM  12445)  and  with  good  installation  practice 
releases SEA from any responsibilities. SEA shall not be held responsible for any failure to execute a correct and safe installation under 
the above mentioned standards.

1) PROPOSED ORDER

 The proposed order shall be accepted only prior SEA approval of it. By signing the proposed order, the Buyer 

shall be bound to enter a purchase agreement, according to the specifications stated in the proposed order.
On the other hand, failure to notify the Buyer of said approval must not be construed as automatic acceptance on the part of SEA.

2) PERIOD OF THE OFFER

 The offer proposed by SEA or by its branch sales department shall be valid for 30 solar days, unless 

otherwise notified.

3) PRICING

 The prices in the proposed order are quoted from the Price List which is valid on the date the order was issued. The discounts 

granted by the branch sales department of SEA shall apply only prior to acceptance on the part of SEA. The prices are for merchandise 
delivered ex-works from the SEA establishment in Teramo, not including VAT and special packaging. SEA reserves the right to change at 
any time this price list, providing timely notice to the sales network. The special sales conditions with extra discount on quantity basis (Qx, 
Qx1, Qx2, Qx3 formula) is reserved to official distributors under SEA management written agreement.

4) PAYMENTS

 The accepted forms of payment are each time notified or approved by SEA. The interest rate on delay in payment shall be 

1.5% every month but anyway shall not be higher than the max. interest rate legally permitted.

5) DELIVERY

 Delivery shall take place, approximately and not peremptorily, within 30 working days from the date of receipt of the order, 

unless otherwise notified. Transport of the goods sold shall be at Buyer’s cost and risk. SEA shall not bear the costs of delivery giving the 
goods to the carrier, as chosen either by SEA or by the Buyer. Any loss and/or damage of the goods during transport, are at Buyer’s cost.

6) COMPLAINTS

 Any complaints and/or claims shall be sent to SEA within 8 solar days from receipt of the goods, proved by adequate 

supporting documents as to their truthfulness.

7) SUPPLY 

The concerning order will be accepted by SEA without any engagement and subordinately to the possibility to get it’s supplies 

of raw material which is necessary for the production; Eventual completely or partially unsuccessful executions cannot be reason for 
complains or reservations for damage. SEA supply is strictly limited to the goods of its manufacturing, not including assembly, installation 
and  testing.  SEA,  therefore,  disclaims  any  responsibility  for  damage  deriving,  also  to  third  parties,  from  non-compliance  of  safety 
standards and good practice during installation and use of the purchased products.

8) WARRANTY 

The standard warranty period is 12 months. This warranty time can be extended by means of expedition of the warranty 

coupon as follows:

SILVER:

  The  mechanical  components  of  the  operators  belonging  to  this  line  are  guaranteed  for  24  months  from  the  date  of 

manufacturing written on the operator.

GOLD:

 The mechanical components of the operators belonging to this line are guaranteed for 36 months from the date of manufacturing 

written on the operator.

PLATINUM:

  The  mechanical  components  of  the  operators  belonging  to  this  line  are  guaranteed  for  36  months  from  the  date  of 

manufacturing written on the operator. The base warranty (36 months) will be extended for further 24 months (up to a total of 60 months) 
when it is acquired the certificate of warranty which will be filled in and sent to SEA S.p.A. The electronic devices and the systems of 
command are guaranteed for 24 months from the date of manufacturing. In case of defective product, SEA undertakes to replace free of 
charge or to repair the goods provided that they are returned to SEA repair centre. The definition of warranty status is by unquestionable 
assessment of SEA. The replaced parts shall remain propriety of SEA. Binding upon the parties, the material held in warranty by the 
Buyer, must be sent back to SEA repair centre with fees prepaid, and shall be dispatched by SEA with carriage forward. The warranty 
shall not cover any required labour activities.
The recognized defects, whatever their nature, shall not produce any responsibility and/or damage claim on the part of the Buyer against 
SEA. The guarantee is in no case recognized if changes are made to the goods, or in the case of improper use, or in the case of tampering 
or improper assembly, or if the label affixed by the manufacturer has been removed including the SEA registered trademark No. 804888.  

 

Furthermore, the warranty shall not apply if SEA products are partly or completely coupled with non-original mechanical and/or electronic 
components, and in particular, without a specific relevant authorization, and if the Buyer is not making regular payments. The warranty 
shall not cover damage caused by transport, expendable material, faults due to non-conformity with performance specifications of the 
products shown in the price list. No indemnification is granted during repairing and/or replacing of the goods in warranty. SEA disclaims 
any responsibility for damage to objects and persons deriving from non-compliance with safety standards, installation instructions or use 
of sold goods. The repair of products under warranty and out of warranty is subject to compliance with the procedures notified by SEA.

9) RESERVED DOMAIN 

A clause of reserved domain applies to the sold goods; SEA shall decide autonomously whether to make use of 

it or not, whereby the Buyer purchases propriety of the goods only after full payment of the latter.

10) COMPETENT COURT OF LAW

 In case of disputes arising from the application of the agreement, the competent court of law is the 

tribunal of Teramo. SEA reserves the faculty to make technical changes to improve its own products, which are not in this price list at any 
moment and without notice. SEA declines any responsibility due to possible mistakes contained inside the present price list caused by 
printing and/or copying. The present price list cancels and substitutes the previous ones. The Buyer, according to the law No. 196/2003 
(privacy code) consents to put his personal data, deriving from the present contract, in SEA archives and electronic files, and he also 
gives his consent to their treatment for commercial and administrative purposes. 

Industrial ownership rights: 

once the Buyer has recognized that SEA has the exclusive legal ownership of the registered SEA brand 

num.804888 affixed on product labels and / or on manuals and / or on any other documentation, he will commit himself to use it in a way 
which does not reduce the value of these rights, he won’t also remove, replace or modify brands or any other particularity from the 
products. Any kind of replication or use of SEA brand is forbidden as well as of any particularity on the products, unless preventive and 
expressed authorization by SEA.

In accomplishment with art. 1341 of the Italian Civil Law it will be approved expressively clauses under numbers:
4) PAYMENTS - 8) GUARANTEE - 10) COMPETENT COURT OF LOW

Sistemi Elettronici

di Apertura Porte e Cancelli

International registered trademark n. 804888

®

Содержание USER 1 - 24V DG R1B

Страница 1: ...o TE Tel 0861 588341 Fax 0861 588344 www seateam com e mail seacom seateam com Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n 804888 67411260 23024055 REV 15 11 2017 24V ELECTRONIC CONTROL UNIT FOR SLIDING GATES AND BARRIERS English ...

Страница 2: ... ENCODER 1 COURTESY LIGHT Cn1 Input Output connector CN2 Limit switch connector CN3 JOLLY 3 connector CN4 Master slave connector CN5 Courtesy light output plug CN6 Motors connector CN7 Batteries connector Quick connection CN8 Power connector CNA RX Receiver connector CNE Encoder connector CNP Programming connector EXP External module connector OK Programming button DOWN Programming button UP Progr...

Страница 3: ...edtorepeattheprogramming pag36 Obligatory jumper without accessory connection Limit switch Cl 1 Yellow 24V Red Common White Limit switch Op 1 Green LIGHT CN5 Max 100mA POWER CN8 24V MOTOR CN6 M Max 200W JUMPERS 1 2 3 4 5 6 7 8 9 10 11 12 13 CN1 ANT COM START PEDST STOP COM PH1 PH2 EDGE AUX COM 24V FL 1 2 3 4 5 6 7 8 9 10 11 12 13 CN1 ANT COM START PEDST STOP COM PH1 PH2 EDGE AUX COM 24V FL Optiona...

Страница 4: ...ing by holding UP for 5 s in the Input check menu until the motor starts Input check menu Fast self learning START command by radio control You can store the START button of the remote control while pressing DOWN for 5 s in the Input check menu Once the writing Press button appears press the button of the transmitter which you want to store for the START command By pressing OK you can exit the men...

Страница 5: ...execute a CLOSING OPENING CLOSING CYCLE PROGRAMMING QUICK START MENU SEA SET MENU SEA SET MENU SEA SET MENU SEA SET MENU SEA SET MENU SEA SET MENU SEA SET MENU SEA SET MENU SEA SET MENU SEA SET OK 1 2 3 5 6 7 8 9 OK OK OK OK OK OK OK OK OK OK OK OK UP UP UP UP UP UP UP OK OK START MENU SEA SET MENU SEA SET MENU SEA SET OK UP LANGUAGE ITALIANO UP MENU SEA SET See page 29 MENU SEA SET OK END 15 MENU...

Страница 6: ...metres Storm 5 metres Storm 6 metres Storm 7 5 metres VergL 4 metres VergL 3 metres Reversible sliding motors Mercury Fast Saturn 1500 Erg Maxi Double Orion No LS Taurus No LS B 224 B 800 No LS B 200 sliding and B 500 Joint Sprint 3 metres Saturn Mercury 800 VergL 5 metres Erg Maxi Erg Verg Sprint 4 metres Sprint 5 metres Storm 5 metres Storm 6 metres Storm 7 5 metres VergL 4 metres VergL 3 metres...

Страница 7: ...d then one of the UPor DOWN buttons Now the gate will automatically execute a CLOSING OPENING CLOSING cycle 4 The self learning is done WORKING TIME SELF LEARNING ON MOTORS WITHOUT LIMIT SWITCH NO LS PRELIMINARY NOTE motors without limit switch must have MECHANICAL STOPS IN OPENING AND CLOSING set on the desired point of stop as in opening as in closing Follow the points from 1 to 4 above shown as...

Страница 8: ...start impulse follows the OPEN STOP CLOSE STOP OPEN logic NOTE 1 To have the automatic closing it is necessary to set a pause time otherwise all the logic will be semi automatic NOTE2 It is possible to choose whether to accept or not the start in pause selecting in the MENU the item 7 START IN PAUSE and choosing ON or OFF By default the parameter is OFF STEPBYSTEPTYPE 2 LOGIC The start impulse fol...

Страница 9: ...Slow intervention Off Intervention excluded 37 SLOWDOWN SENSITIVITY xxx xxx 47 ENCODER PAR 1 48 ENCODER TOT 1 0 100 63 DECELERATION Setting from 30 to 100 Setting from 30 to 100 Setting from 30 to 100 Setting from 30 to 100 Setting from 30 to 100 Opening torq Closing torq Adjusts the intervention time of the Encoder in opening Disabled Adjusts the intervention time of the Encoder in closing Disabl...

Страница 10: ...e gate before forcing 85 PREFLASHING 86 FLASHING LIGHT 87 FLASHING LIGHT AND TIMER 88 COURTESY LIGHT 89 TRAFFIC LIGHT RESERVATION 90 PEDESTRIAN OPENING 91 PEDESTRIAN PAUSE 92 TIMER 0 0 5 0 Only closing Buzzer Normal Light Always Off On In cycle 1 240 Off Off on 20 100 Start Off Off On photo2 On pedestrian entry 1 240 Pre flashing only active before closing Pre flashing time Normal Control lamp Alw...

Страница 11: ...e in opening and closing Photocell active in closing The photocell gives a command to close during opening pause and closing The photocell charging the pausing time The photocell stops in closing and closes when released Closing Delay pause time If the photocell is occupied during opening pause or closing the gate reopens completely and closes without observing the pause time Shadow loop Until occ...

Страница 12: ... repeats the pause timebefore closing The loop function is OFF during closing Stop The photocell is active also before opening Stop N O only for VERG barrier It modifies the PHOTO2 input into a Normally Open stop button 100 EDGE1 8K2 Edge is active and pro tected by a 8K2 resistor Normal 99 PHOTO OFF IN CLOSING 0 50 0 Setting from 0 to 50 Normal N C contact Normal 8K2 Double Photo 1 10K Photo 1 10...

Страница 13: ...es 120 BASIC MENU MENU SP Default SET Description Set Value From 30 to 100 80 119 DISPLAY WRITING SPEED Note 1 The indicates that the default value or the menu may change depending on the selected motor type Note 2 After initialization the parameters motor type and limit switch type remain son the value chosen in the setup program Note 3 Display writing speed set on 30 keeps writing slow Display w...

Страница 14: ...ct is a N C Contact The contact must be a N C Contact When activating the related command on the display SET lights up the input works If SET is always on make sure that the contact is a N C Contact Exit menu OK OK MENU FUNCTION TABLE CHECK USER 1 24V DG R1B INPUTS To access the Menu for input check keep pressed OK for about 5 seconds OK 0 0V Batteries Voltage Level Note If the Stop Photocell 1 an...

Страница 15: ... MENU SEA MENU SEA SET MENU SEA SET MENU SEA SET SET START PEDESTRIAN START EXTERNAL MODULE STOP DELETE A TRANSMITTER 0 OK OK CLEAR MEMORY OK PRESS BUTTON STORED STORED STORED STORED PRESS BUTTON PRESS BUTTON PRESS BUTTON If you want to program the pedestrian start as second channel If you want to delete a single transmitter If you want to delete the whole memory If you want to program the activat...

Страница 16: ...Accessories max 750mA COM 0V PH1 Photocell contact 1 PH2 Photocell contact 2 Note Self test connect the TX to the AUX clamp and activate the Autotest function The photocell 1 default setting is FOTO CLOSE and the photocell 2 one is FOTO OPEN The photocell 2 can be set also asTIMER seeTIMER function Note3 On the 26 FOTOTEST menu you can also activate the self test even on the single photocell OPTIO...

Страница 17: ...pens the contact causing a partial inversion of the movement both in opening and in closing The Safety Edge output can be set only in closing only in opening or both directions Note1 Note1 Through the on board display or the JOLLY 3 programmer it is possible to activate the balanced edge 8K2 in this case the edge contact is controlled by a special resistance value revealing the eventual involuntar...

Страница 18: ...me of loop detector 2 reader 8 Contact photocell 2 N C 6 Common Note Please set 98 PHOTOCELL2 LOOP2 menu to Shadow loop Free exit loop loop 3 Connecting scheme of loop detector reader 3 Contact start n o 6 Common C1 CONTACT OPEN C2 CONTACT CLOSED 12 24 V C 0 V SAFETY LOOP CONNECTIONS 6 Brown Green Pink Yellow Grey NOTE For both MagLock types it is necessary to set menu 94 24V AUX on negative brake...

Страница 19: ...quick c o n n e c t a b l e charger to an old battery charger you must use the CNQ adapter cable IMPORTANT To connect the batteries always use the battery charger CONNECTION OF BATTERIES TO BATTERY CHARGER CARD 28V Battery charger Positive battery Negative battery charger Battery current mA Battery Ah Insert two 12V batteries connected in series 800 360 200 12 or 16 7 2 Specifications of optional ...

Страница 20: ...ER control unit Note 1 The master and slave settings on the control unit are present in the special menu selecting 105 MASTER SLAVE Note 2 All these operations can also be managed through the JOLLY3 programmer Note 3 On the SLAVE it is possible to set the following functions only torque speed motor type slowdown speed acceleration deceleration position recovery AUX and motor inversion All other pa...

Страница 21: ...l unit will automatically realize if limit switches are present or not Through the on board display or through the JOLLY 3 programmer it is possible to activate the ani intrusion function This function is lied to the presence of at least one limit switch which when free forces the motor to re close LIMIT SWITCH AND SENSOR BARRIERS Limit Switch CN2 Note1 The sensitivity is adjustable both in openin...

Страница 22: ...itch off timeout has expired or by turning off and on again the control unit Once the password has been activated the menus of the display can be only displayed but not set To unlock them you must enter the correct password in the 34 PASSWORD menu if the password is wrong the message Error will appear At this point if the password has been entered correctly the menus will be unlocked and it will b...

Страница 23: ...onnections on the control unit Check the operation of both limit switches and or correspon dence between movement direction of the motor and engaged limit switches Check connections and or conditions of the lamp FAILURE MOTOR FAILURE24 FAILURE24VAUX FAILURE SELF TEST FAILURE LIMIT SWITCH FAILURE FLASHING LIGHT Signals Check for obstacles or points of friction on the gate NOTE the fault is reset by...

Страница 24: ...n the released position b There is an obstacle a Re lock the motor b Remove obstacle Gate doesn t reach the complete Open Closed position a Wrong setting of the limit switches b Erroron programming c Gate is stopped by an obstacle d Torque too low e Gate is too heavy forautomaticslow down a Set limit switches b Repeat programming c Remove obstacle d Increase torque parameter e Set the slow down on...

Страница 25: ...se time Gate doesn t have power to close or reach limit switch a Slowdown not possible for that site due to heavy gate or inclination or not new installation a Put SlowDown in OFF Obstruction in gates path does not cause gate to stop and reverse a Force adjustment needed a Refer to the Adjustment section to conduct the obstruction test and performthe proper force adjustment that is needed sensitiv...

Страница 26: ...ing must be made with appropriate vehicles WARRANTYLIMITS For the guarantee see the sales conditions on the official SEAprice list SEA reserves the right to make any required modification or change to the products and or to this manual without any advanced notice obligation Page for both installer and user WAREHOUSING TEMPERATURES Tmin TMax Dampnessmin DampnessMax 5 Not condensing 90 Not condensin...

Страница 27: ...automated system s security and efficiency if components used are not produced by SEAS p A 10 For maintenance strictly use original parts by SEA 11 Do not modify in any way the components of the automated system 12 The installer shall supply all information concerning system s manual functioning in case of emergency and shall hand over to the user the warnings handbook supplied with the product 13...

Страница 28: ...cturing written on the operator PLATINUM The mechanical components of the operators belonging to this line are guaranteed for 36 months from the date of manufacturing written on the operator The base warranty 36 months will be extended for further 24 months up to a total of 60 months when it is acquired the certificate of warranty which will be filled in and sent to SEA S p A The electronic device...

Страница 29: ...or to be assembled with other machinery to create a machine under the provisions of Directive 2006 42 CE è conforme ai requisiti essenziali di sicurezza relativi al prodotto entro il campo di applicabilità delle Direttive Comunitarie 2006 95 CE e 2004 108 CE it is conforming to the essential safety requirements related to the product within the field of applicability of the Community Directives 20...

Страница 30: ...e highest quality levels and for your complete satisfaction Thanks for choosing SEA Cet article a été produit suivant des procédures d usinage strictes et il a singulièrement été testé afin de garantir les plus hauts niveaux de qualité pour votre satisfaction Nous vous remercions d avoir choisi SEA Este articulo ha sido producido siguiendo rigidos procedimientos de elaboracion y ha sido probando s...

Страница 31: ...Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n 804888 Note Notes Note Notas Anmerkung ...

Страница 32: ...ettronici di Apertura Porte e Cancelli International registered trademark n 804888 SEA S p A Zona industriale 64020 S ATTO Teramo ITALY Tel 39 0861 588341 r a Fax 39 0861 588344 www seateam com seacom seateam com ...

Отзывы: