41
START - STOP - PEDESTRIAN START - ANTENNA - PHOTOCELL
START (N.O.) The
START is connected between the clamps 2 and 3 of the CN 1 terminal.
An impulse given to this contact opens and closes the automation depending onthe selected logic it can be given by a key switch,
a keypad, etc. To connect the other devices refer to the related instructions leaflets. (ie. loop detectors and proximity switches).
Note1
: In DEAD MAN logic it is necessary to keep pressed the Start for the opening of the automation.
Note2
:
In 2 BUTTONS logic this button performs the opening.
STOP (N.C.) The STOP is connected between the clamps 2 and 5 of the CN1 terminal .
The pressure on this button immediately stops the motor in any condition/position. A start command is needed to
re-start the movement. After a stop the motor always re-starts in closing.
Can be activated through on-board display or through the Jolly programmer. In both cases it’s a N.O. contact
which provoques the opening of the automation keeping it open until it is activated. When it’s released, the gate
attends the set pausing time and executes the reclosing. The TIMER command can be activated on the inputs
FOTO2, START PEDESTRIAN.
Note1
: When activated on the pedestrian entry, the pedestrian will be disabled also on the radio transmitter.
Note2
: In case of intervention of a security device during the timer (Stop, Ammeter, Edge), to restore the movement it will be
necessary to give a start impulse.
Note3
: In case of no power supply with open gate and active Timer the control unit will restore its use, otherwise if during restore
of the power supply the TIMER is not activated it will be necessary to give a start impulse for the reclosing.
TIMER
PEDESTRIAN START (N.O.) The pedestrian start can be connected
between the clamps 2 and 4 of the CN1 terminal .
This input allows a partial opening the opening space can be set through the
on-board display or through the JOLLY device.
Note1
: The contact for partial opening is a N.O. Contact (Normally open).
Note2
:In 2 BUTTONS logic it is necessary to keep pressed the Start Ped. to re-close the automation.
Note3
: In dead man logic this button executes the re-closing if you keep it pressed.
Note4
: When closed during pause, the gate will reclose only after this input has been reopened.
TIMER activation
: This input can be transformed into TIMER (See TIMER).
Photocell 1 and Photocell 2 Connections
+ = 24V (Accessories) max 750mA COM = 0V PH1 = Photocell contact 1
PH2 = Photocell contact 2
Note
: Self-test: connect the TX to the AUX clamp and activate the Autotest function. The
photocell 1 default setting is FOTO CLOSE and the photocell 2 one is FOTO OPEN. The
photocell 2 can be set also as TIMER (see TIMER function).
Note3:
On the 26-FOTOTEST menu you can also activate the self-test even on the single
photocell.
OPTIONS ON FOTO1 and FOTO2 adjustable on on- board display or with
JOLLY terminal.
FOTO CLOSE activation (“Closing”)
: if occupied, reverses the movement in closing,
during pause it prevent the closing.
Activation repeat pause (“Pause reload”)
: If occupied, during pause it recharges the
timer of pause. In closing it reverses the movement.
FOTO OPEN AND CLOSE activation (“Opening and closing”):
If activated the photocell
blocks the movement as long as it’s busy,
when released the opening continues.
FOTO PARK activation (“Stop and close”)
: in opening it is not active; in pause are
activated it commands the closing when released, otherwise it’s not active; in closing it stops
the movement as long as it is busy, when released the closing continues.
FOTO STOP activation (“Stop”)
: When activated before the opening the photocell blocks
the automation as long as it is busy, during the opening it will be ignored. In closing the
intervention of the photocell causes the reopening.
Activation PHOTO CLOSE IMMEDIATELY (“Close”)
: The photocell stops the gate as
long as it is occupied in both opening and closing, when released it gives a closing command
(Closing one second after release of the photocell ).
“Delay pause time”activation
:
If the photocell is occupied during opening, pause
or closing, the gate reopens completely and closes without observing the pause time.
Antenna
Common
Start
Start ped.
Stop
Common
Photocell 1
CN1
1
2 3 4 5
6 7 8
Photocell 2
RX1
RX2
TX1
TX2
CN1
9 10 11 12 13
Common
24V (Accessories)
Options AUX 24V max 200mA can be set with
on-board Display or with Jolly device.
Through the Jolly programmer it is possible to chose when
having tension on the AUX output. The options are: “Always”,
“In cycle”, “Opening”, “Closing”, “In pause”, “Fototest”
and
“In cycle and fototest”
.
When using control units with batteries
and/or solar panels, we recommend connecting the accesso-
ries which are not used when operator stands still (e.g. photocells) to a
AUX output, setting the option “In cycle”. With this setting you can save
energy by lowering power consumption in stand-by, increasing the
autonomy of the system.