32
WORKING TIMES SELF-LEARNING
1 240
Off
Off
Off
On
Off
Off
On
Off On
Off
Off
Off On
Off
Automatic
2 buttons
Safety
Dead man
Open-stop-close-stop-open
Open-stop-close-open
Press OK to return to the display of the firmware version
and to the one of inputs state
Press OK to enter the special menu
8 - START IN PAUSE
6 - LOGIC
7 - PAUSE TIME
5 - REVERSE MOTOR
9 - PROGRAMMING
10 - TEST START
15 - END
16 - SPECIAL MENU
Synchronized right motor
Automatic
Step by step type 1
Step by step type 2
Two buttons
Safety
Dead man
Setting from 1s to 4min.
OFF
(semi-automatic logics)
In pause start is not acceped
In pause start is accepted
Start command
Times learning start
Synchronized left motor
Open-stop-
close-open
MENU
SET
Default
Description
Set value
WORKING TIME SELF-LEARNING ON MOTORS WITH LIMIT-SWITCH
PRELIMINARY NOTE:
When using magnetic limit switches (such as on B-200 model), make sure that
the control unit is set on «magnetic limit switch» before learning:
MENU 104 - SELECT LIMIT SWITCH -
“Magnetic”
1) Turn off the power supply, release the motor and place the door (or the barrier) manually at its mid run
2)
Reset the mechanical lock
3)
Select 9 - PROGRAMMING on the display, press OK and then one of the UP or DOWN buttons.
Now the gate will automatically execute a CLOSING-OPENING-CLOSING cycle
4)
The self-learning is done
WORKING TIME SELF-LEARNING ON MOTORS WITHOUT LIMIT-SWITCH (NO LS)
PRELIMINARY NOTE: motors without limit-switch must have
MECHANICAL STOPS IN OPENING AND
CLOSING
set on the desired point of stop as in opening as in closing
Follow the points from 1 to 4 above shown as in the procedure for limit-switch motors
ATTENTION:
If the motor starts in opening, remove and re-put power supply, select on the display
5-REVERSE MOTOR and through the UP and DOWN buttons select ON; if you have the Jolly3 programmer,
activate the motor exchange function and, only if present, limit-switch exchange function. If the motor starts
in closing and stops, remove the power supply and reverse the motor cables, then repeat the programming
procedure
ATTENTION:
This procedure is potentially dangerous and should only be performed by qualified
personnel in safety conditions
The control unit is pre-set with
DEFAULT
settings. To start the control unit with the
DEFAULT
settings
just keep pressed the
UP
and
DOWN
buttons at the same time power supplying the control unit
till the display shows the message
«INIT
». The
DEFAULT
settings are shown in the Menues table
Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
English