37
MENU SP
Default
SET
Description
Set Value
98 - PHOTO2
Opening
Opening and closing
Closing
Stop and close
Close
Pause reload
Active in opening and closing
Photocell active in closing
The photocell gives a command
to close during opening, pause
and closing
The photocell charging
t h e p a u s i n g t i m e
The photocell stops in closing
and closes when released
Delay pause time
If the photocell is occupied
during opening, pause or
closing, the gate reopens
completely and closes without
observing the pause time
Shadow loop
Until occupied with open gate,
it prevent reclosing. The loop
function is OFF during closing
Shadow loop RP
Until occupied with open gate,
it prevent reclosing. Once
released, the gate repeats the
pause timebefore closing.
The loop function is OFF during
closing
Stop
The photocell is active
also before opening
Stop N.O.
(only for VERG barrier)
It modifies the PHOTO2 input
into a Normally Open stop button
100 - EDGE1
8K2
Edge is active and pro-
tected by a 8K2 resistor
Normal
99 - PHOTO OFF
IN CLOSING
0 50
0
Setting from 0 to 50
Normal N.C. contact
Normal
8K2 Double
Photo 1 10K
Photo 1 10K Double
Allows to connect two
edges protected by a 8K2
resistor
Edge works as a photocell
protected by a 10K resistor
Allows to connect two
photocells protected by a
10K resistor
104 - SELECT
LIMIT SWITCH *
Mechanical limit switch
Magnetic limit switch
Mechanical
Magnetic
Mechanical
102 - EDGE
DIRECTION
Opening and closing
Only in Closing
Only in Opening
Active in opening and closing
Active only in Closing
Active only in Opening
Opening
and
closing
Stop and Open
If the photocell is activated during
opening, the gate stops and con-
tinues to open when released.
The photocell is ignored in
closure