Sistemi Elettronici
di Apertura Porte e Cancelli
International registered trademark n. 804888
®
Fig. 52
SEA can not be deemed responsible for any damage or
accident caused by product breaking, being damages or
accidents due to a failure to comply with the instructions herein.
Read the general instructions attentively.
SAFETY GATE
For a correct and safe installation it is strongly recommended to
install a Safety Gate,
which allows the fulfilment of the force
diagram included in the norm EN 12453
and consequently the
test and start of the whole installation.
Fig. 53
ENGLISH
17. PERIODICAL MAINTENANCE
Check the oil level
(Trasparent cap n.14 in Fig. 3)
Annual
Change the oil
Verify the functionality of the by-pass valves
(check the force in opening and closing)
Check the release function
Verify the slowdown regulation (where present)
Check the correct drain of the rainwater
Check the integrity of the connection cables
Grease all the moving parts
Grease the rotation axis of the box as in Fig.50
4 years
Annual
Annual
Annual
Annual
Annual
Annual
Annual
SAFETY GATE
SAFETY PRECAUTIONS:
All electrical work should conform to current regulations. A 16 A
0,030 A differential switch must be incorporated into the source
of the operators main electrical supply and the entire system
properly earth bonded. Always run mains carrying cables in
separate ducts to low voltage control cables to prevent mains
interference.
SPARE PARTS:
To obtain spare parts contact:
SEA S.p.A. - Zona Ind.le, 64020 S. ATTO Teramo Italia
SEA
reserves the right to do changes or variations that may be
necessary to its products with no obligation to notice.