background image

RELEASE PLUS

13.2. 

Grease the hinge (A) and mount the release system under 

the leaf device using the 5 furnished screws (Fig. 42).

Sistemi Elettronici

di Apertura Porte e Cancelli

International registered trademark n. 804888

®

Fig. 38

Fig. 40

2

Fig. 39

Fig. 41

A

12. I

INSTALLATION OF THE OPERATOR IN 

THE CARRYING BOX

12.1. 

Insert manually the operator

 

into the

 

carrying box (Fig. 38) 

also insert the splined shaft of the operator into the splined bush 
of the box and fix the operator with the special screws as in 
Fig.40.

N.B.

: It is advisable to weld the crank with the crank shaft after 

having also installed the Jack, to use the whole available run and 
the point of beginning of the desired slowdown (version with 
hydraulic slowdown). 
Before welding, make sure that one of the level of the crank shaft 
corresponds with a side of the crank (see fig.39 and 40) to 
guarantee the maximum angle with the mechanical stops Kit.

N.B.

: If the Jack is not installed immediately but in a second time, 

it is recommended to weld the crank shaft and the crank during 
the installation of the Jack.   

Carry out the electrical connections to the control unit as 
described in the instructions supplied with SEA control unit.

Fig. 42

A

Fig. 43

1

ENGLISH

Release

Release Plus

14. ADJUSTABLE MECHANICAL STOPS

20

67411740

12.1.

 Connect the hydraulic tubes with the hydraulic unit and the 

jack (Fig.21, Fig.22, Fig.23).
After the installation of the above mentioned carrying box, of the 
gate and the operator, try to move the gate   slowly by hand 
verifying that there are no irregular frictions and that the 
movement is uniform for the whole range.

Notice:

 To do this last operation, release the operator as 

described in the related paragraph. 

13. RELEASE MOUNTING 

For the Jack are foreseen two types of release: 
RELEASE (with personalised key) and RELEASE PLUS 
(with DIN key).

RELEASE

13.1. 

Grease the hinge (A) and mount the release system 

under the leaf device using the 4 furnished screws (Fig. 41) 

REV 01 - 03/2015

Содержание JACK 1200

Страница 1: ...eramo ITALY Tel 0861 588341 r a Fax 0861 588344 Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark n 804888 67411740 Operatore oleodinamico interrato Underground hydra...

Страница 2: ...ons with slow down only The wheeling unit is composed by a double piston connected to a rack which engages with the pinion of the leaf dragging shaft Gates up to 2 meters long can be securely locked u...

Страница 3: ...er hinge alone is sufficient to install the unit those which are unnecessary can be eliminated the lower and that in the middle if exists E as the limit switches are not provided within the actuator i...

Страница 4: ...a level to make it perfectly horizontal to the ground Fig 10 and perpendicular to the axis of the gate Fig 11 Hydraulic tubes sheath Hydraulic unit Pivot Bush U shaped bar Leaf 4 MOUNTING OF THE LEAF...

Страница 5: ...xis of the jack 5 H Y D R A U L I C U N I T B O X WA L L INSTALLATION Fig 19 5 1 Connect the hydraulic tubes with the hydraulic unit and the jack Fig 21 Fig 22 Fig 23 After having installed the box th...

Страница 6: ...o g F Yellow e t n m t s i u n j d c a lo e s c r i n o g F Braking regulation screw Opening closing Blocking screw for braking regulation 17 67411740 Copper tube Flexible tube 6 BLEED CAPREPLACEMENT...

Страница 7: ...m the hydraulic circuit until non emulsified oil appears d tighten the air bleed screw before the operator completes the opening cycle e command closing of the gate f during closing of the gate loosen...

Страница 8: ...ong the surface of the contact avoiding the welding next to the threaded holes Fig 32 10 4 Introduce the buckle of creeping in the box and fix it with the special screws Fig 33 10 5 Insert the units a...

Страница 9: ...th the mechanical stops Kit N B If the Jack is not installed immediately but in a second time it is recommended to weld the crank shaft and the crank during the installation of the Jack Carry out the...

Страница 10: ...XAMINATION The points pointed by arrows in Fig 52 are potentially dangerous The installer must take a thorough risk examination to prevent crushing conveying cutting grappling trapping so as to guaran...

Страница 11: ...he release function Verify the slowdown regulation where present Check the correct drain of the rainwater Check the integrity of the connection cables Grease all the moving parts Grease the rotation a...

Страница 12: ...against the external of the release making come out the handle of the lock until it reaches the stop Fig 57 Move the leaf and make return the handle of the release in its original position and extract...

Страница 13: ...iportata sull operatore La garanzia di base 36 mesi sar estesa per ulteriori 24 mesi fino ad un totale di 60 mesi qualora venga acquistato il certificato di garanzie che dovr essere compilato e risped...

Страница 14: ...the operator PLATINUM The mechanical components of the operators belonging to this line are guaranteed for 36 months from the date of manufacturing written on the operator The base warranty 36 months...

Страница 15: ...sed by improper use or different use in respect to the intended one 4 The mechanical parts must be comply with Directives Machine Regulation 2006 42 CE and following adjustments Low Tension 2006 95 CE...

Страница 16: ...ando la puerta est completamente abierta 15 Todo el mantenimiento reparaci n o controles deber n ser realizados por personal cualificado Evitar cualquier intente a reparar o ajustar En caso de necesit...

Страница 17: ...highest quality levels and for your complete satisfaction Thanks for choosing SEA Este articulo ha sido producido siguiendo rigidos procedimientos de elaboracion y ha sido probando singolarmente a fi...

Страница 18: ..._________________________________ Nome e Cognome First and Family Name_________________________________ Indirizzo Address ____________________________________________________ INSTALLATORE INSTALLER Fi...

Страница 19: ......

Страница 20: ...A Zona industriale 64020 S ATTO Teramo ITALY Tel 0861 588341 r a Fax 0861 588344 www seateam com seacom seateam com Sistemi Elettronici di Apertura Porte e Cancelli International registered trademark...

Отзывы: