![Sea Recovery Aqua Mini 170 Скачать руководство пользователя страница 62](http://html1.mh-extra.com/html/sea-recovery/aqua-mini-170/aqua-mini-170_owners-manual_1221266062.webp)
7. If the contactor does not operate mechanically, then measure the DC voltage between A1 and A2 terminals on
the High Pressure Pump Motor contactor coil. It should read 12V DC when activated.
8. If the contactor coil is receiving 12V DC but inoperative then the contactor’s coil may be bad. Replace the
contactor.
9. If 12V DC is not present when the High Pressure Pump is activated, trace the orange and orange/black wires
to the main circuit board and measure the DC voltage at the terminals. It should read 12V when activated.
Booster Pump Abnormalities
If the Booster Pump electric motor fails to operate, follow these steps to isolate the problem.
1. Ensure that the system is receiving proper power from the power source.
2. Press “Booster Pump” switch to activate the motor. Do not press any other switch.
3. Measure the AC voltage between Terminals 1 and 2 on the main terminal strip in the controller.
4. If the voltage measured in the step 3 above matches the system voltage, then problems may be in the power
cable attached to the motor or the motor internal wiring or windings.
5. If low or no voltage is present in step 3 above, then check for proper operation of the Booster Pump Contactor.
To deactivate the contactor, press the “Stop” switch twice. To activate the contactor again, press the “Booster
Pump” switch.
6. If the contactor is mechanically operating, but no voltage is present at the motor terminal (step 3 above), then
the Booster Pump Motor contactor may be at fault.
7. If the contactor does not operate mechanically, then measure the DC voltage between A1 and A2 terminals on
the Booster Pump Motor contactor coil. It should read 12V DC when activated.
8. If the contactor coil is receiving 12V DC but inoperative then the contactor’s coil may be bad. Replace the
contactor.
9. If 12V DC is not present when the Booster Pump is activated, trace the yellow and yellow/black wires to the
Control Printed Circuit Board and measure the DC voltage at the terminals. It should read 12V when activated.
Electrical and Electronic Circuit Abnormalities
The Start Switch is pressed, but the system does not attempt to start.
1. System is in Fresh Water Flush Mode. Press Stop to exit Fresh Water Flush Mode. Press Start to operate the
system.
2. The LCD on the Touch Pad is not illuminated
• Reset the system circuit breaker.
• There is no main Power to the system from the Power Source, investigate, and correct.
3. Blown Fuse in controller. Check and Replace fuse if blown.
4. Improper wiring. Ensure that system is wired correctly and that there are no loose wire connections.
5. Inadequate power source to the system
• Ensure that the voltage does not drop below the industry standard of 10% of the full operating voltage set for
the system. If the voltage drops below this standard during the system startup, the system will not start. High
current is necessary to “excite” the electric motors. At the time of attempting to start the electric motors, they
will consume high current. This may cause the voltage from the Power Source to drop dramatically for a fraction
of a second which can be enough to cause the electronic circuit to shut off.
• For D.C. systems it is instantaneous, and you will not hear or see this occur. D.C. systems ensure that the
battery bank is fully charged and ensure that the wire size feeding the system is sufficient in diameter to carry
the current without losing voltage. A.C. systems will usually result in the Generator loading down and the
Generator R.P.M. slowing down.
• Provide adequate power to the system.
6. Defective Start Switch on Touch Pad.
• Test with Substitute Touch Pad.
• Replace Touch Pad if one or more lamps or switches are found to be inoperable.
Sea Recovery Aqua Mini 170, 350, 550 and 750
60
Содержание Aqua Mini 170
Страница 2: ......
Страница 3: ...Sea Recovery Aqua Mini 170 350 550 and 750 Owner s Manual Sea Recovery Corp Manual PN B651220001B...
Страница 4: ......
Страница 12: ......
Страница 18: ......
Страница 28: ......
Страница 48: ......
Страница 66: ......
Страница 71: ...Wiring Diagram Aqua Mini 24vdc 69 Electrical...
Страница 72: ...Wiring Diagram Aqua Mini 110 220 VAC single phase Sea Recovery Aqua Mini 170 350 550 and 750 70...
Страница 73: ...71 Electrical...
Страница 74: ......
Страница 90: ......
Страница 97: ...Chapter 12 Exploded Parts View 95...
Страница 106: ...13 7 16 9 11 6 7 10 15 14 12 8 1 7 2 15 4 5 14 1 8 9 16 6 17 18 Sea Recovery Aqua Mini 170 350 550 and 750 104...
Страница 108: ...9 11 14 2 13 4 17 1 6 18 3 16 15 5 12 8 10 9 11 3 16 15 7 Sea Recovery Aqua Mini 170 350 550 and 750 106...
Страница 131: ...12 8 9 7 3 6 10 17 23 1 11 25 5 2 20 13 16 18 21 15 14 22 4 24 7 19 23 24 129 Exploded Parts View...
Страница 133: ...12 8 9 7 3 6 10 17 23 1 11 25 5 2 20 13 16 18 21 22 4 24 7 19 23 24 14 15 131 Exploded Parts View...
Страница 135: ...12 8 9 7 3 6 10 17 24 26 5 2 20 13 18 22 23 4 25 7 19 24 25 21 14 16 1 15 11 133 Exploded Parts View...
Страница 146: ...1 1 15 11 5 13 6 14 11 5 16 3 8 7 9 4 12 10 2 Sea Recovery Aqua Mini 170 350 550 and 750 144...
Страница 148: ...5 7 11 2 1 2 10 6 3 8 4 9 6 3 Sea Recovery Aqua Mini 170 350 550 and 750 146...
Страница 153: ...12 8 9 2 10 13 1 3 5 4 14 11 6 15 7 151 Exploded Parts View...
Страница 155: ...1 153 Exploded Parts View...
Страница 162: ......
Страница 163: ...Chapter 13 Appendix 161...
Страница 164: ......
Страница 165: ......
Страница 166: ...FCC Compliance 163 Appendix...
Страница 170: ...Sea Recovery 2630 E El Presidio Street Carson CA 90810 sales searecovery com www searecovery com Manual PN B651220001B...